background image

10

Ordering information

Table 2:

BayStack 460-24T-PWR Power over Ethernet Switch ordering information

Order No. 

Description

AL2001x20**

BayStack 460-24T-PWR Power over Ethernet Switch (24 10/100BASE-TX plus 1 MDA slot and 1 cascade module slot).

AL2033011

BPS2000-4TX 4-port 10/100 MDA 

AL2033012

BPS2000-4FX 4-port 100BASE-FX MDA w/mini MT-RJ-type connectors 

AL2033013

BPS2000-2FX 2-port 100BASE-FX MDA w/SC-type connectors

AL2033010

BayStack 400-ST1 Cascade Module (includes cascade cable)

AL2018001

BayStack 400-SRC Cascade Return Cable (1 meter) 

AL2018002

BayStack 400-SSC Spare Cascade Cable (18 inch) 

AL2018004

BayStack 400-SRC Cascade Return Cable (3 meter) 

AL2033005^

BayStack 450-1SX 1-port 1000BASE-SX Single PHY MDA

AL2033006^

BayStack 450-1SR 1-port 1000BASE-SX Redundant PHY MDA

AL2033007^

BayStack 450-1LX 1-port 1000BASE-LX Single PHY MDA

AL2033008^

BayStack 450-1LR 1-port 1000Base-LX Redundant PHY MDA

AL2033009^

BayStack 450-1GBIC MDA (GBIC not included with MDA)

AA1419001~

1-port 1000BASE-SX Gigabit Interface Connector (GBIC), SC connector

AA1419002~

1-port 1000BASE-LX Gigabit Interface Connector (GBIC), SC connector

AA1419003~

1-port 1000BASE-XD Gigabit Interface Connector (GBIC)-40km SC connector

AA1419004~

1-port 1000BASE-ZX Gigabit Interface Connector (GBIC)-70km SC connector

AL2033014***

BPS2000-1GT 1-port 1000BASE-TX MDA

AL2033015***

BPS2000-2GT 2-port 1000BASE-TX MDA

AL2033016***

BPS2000-2GE 2-port Small Form Factor GBIC MDA (supports up to two Small Form Factor GBICs)

AA1419013

1-port 1000BASE-SX Small Form Factor GBIC (LC connector) 

AA1419014

1-port 1000BASE-SX Small Form Factor GBIC (MT-RJ connector)

AA1419015

1-port 1000BASE-LX Small Form Factor GBIC (LC connector)

AA1419025

1-port 1000BASE-CWDM Small Form Factor GBIC—1470nm Wavelength (40km), LC connector

AA1419026

1-port 1000BASE-CWDM Small Form Factor GBIC—1490nm Wavelength (40km), LC connector

AA1419027

1-port 1000BASE-CWDM Small Form Factor GBIC—1510nm Wavelength (40km), LC connector

AA1419028

1-port 1000BASE-CWDM Small Form Factor GBIC—1530nm Wavelength (40km), LC connector

AA1419029

1-port 1000BASE-CWDM Small Form Factor GBIC—1550nm Wavelength (40km), LC connector

AA1419030

1-port 1000BASE-CWDM Small Form Factor GBIC—1570nm Wavelength (40km), LC connector

AA1419031

1-port 1000BASE-CWDM Small Form Factor GBIC—1590nm Wavelength (40km), LC connector

AA1419032

1-port 1000BASE-CWDM Small Form Factor GBIC—1610nm Wavelength (40km), LC connector

AA1419033

1-port 1000BASE-CWDM Small Form Factor GBIC—1470nm Wavelength (70km), LC connector

AA1419034

1-port 1000BASE-CWDM Small Form Factor GBIC—1490nm Wavelength (70km), LC connector

AA1419035

1-port 1000BASE-CWDM Small Form Factor GBIC—1510nm Wavelength (70km), LC connector

AA1419036

1-port 1000BASE-CWDM Small Form Factor GBIC—1530nm Wavelength (70km), LC connector

AA1419037

1-port 1000BASE-CWDM Small Form Factor GBIC—1550nm Wavelength (70km), LC connector

AA1419038

1-port 1000BASE-CWDM Small Form Factor GBIC—1570nm Wavelength (70km), LC connector

AA1419039

1-port 1000BASE-CWDM Small Form Factor GBIC—1590nm Wavelength (70km), LC connector

AA1419040

1-port 1000BASE-CWDM Small Form Factor GBIC—1610nm Wavelength (70km), LC connector

AA1419001

1-port 1000BASE-SX Gigabit Interface Connector (GBIC), SC connector

AA1419002

1-port 1000BASE-LX Gigabit Interface Connector (GBIC), SC connector

AA1419003

1-port 1000BASE-XD Gigabit Interface Connector (GBIC)-40km SC connector

AA1419004

1-port 1000BASE-ZX Gigabit Interface Connector (GBIC)-70km SC connector

AL2018008

2-pin cable from BayStack 460-24T-PWR to BayStack 10 PSU (for RPSU and load-sharing capability)

DY4311015

Power splitters for i200X phones—bag of 12

* These features will be supported on future software releases available free from the Web.

** The seventh character (x) of the switch order number must be replaced with the proper code to indicate desired product nationalization:

“A” – No power cord included
“B” – Includes European “Schuko” power cord common in Austria, Belgium, Finland, France, Germany, The Netherlands, Norway, and Sweden
“C” – Includes power cord commonly used in the United Kingdom and Ireland
“D” – Includes power cord commonly used in Japan
“E” – Includes North American power cord
“F” – Includes Australian power cord, also commonly used in New Zealand and the People’s Republic of China

^ Supports two output (egress) queues
~ One of these GBICs can be installed in the BayStack 450-1GBIC MDA
***Supports up to eight output (egress) queues

Содержание BayStack 460-24T-PWR

Страница 1: ... devices badge readers Figure 1 The switch has all of the features of the BayStack Business Policy Switch such as advanced Quality of Service QoS and high resiliency with the addition of Power over Ethernet capability It enables enter prise customers to power devices while maintaining connectivity to standard 10 100 Mbps Ethernet devices such as BayStack 460 24T PWR Power over Ethernet Switch Nort...

Страница 2: ...for a separate cable connecting the IP device to a power outlet Significant space and cost savings Traditionally a mid span patch panel device connects to a standard Ethernet switch and the device sends power over standard UTP cat 5 cable In essence two units are needed for Power over Ethernet capability In contrast the BayStack 460 Switch integrates standard LAN switch functionality with the powe...

Страница 3: ...witch or across a stack Protocol based VLANs allow switch ports to be assigned to a broadcast domain based on the protocol information within the packet These VLANs can localize broadcast traffic and assure that the specified protocol type packets are sent only to the protocol based VLAN ports Shared VLAN SVL and individual VLAN IVL learning is supported With SVL support all VLANs in the switch sh...

Страница 4: ...ce RADIUS for switch security management IP Manager List limits access to the manage ment features of the BayStack 460 Switch by a defined list of IP addresses providing greater network security and manageability SNMPv3 provides user authentication and data encryption for higher security It also offers secure configuration and monitoring For even greater security the BayStack 460 Switch also suppo...

Страница 5: ...power systems please visit their Web site at www intergynes com For information on how to purchase NES DC power system please e mail Invensys at us_dc_quotes energy invensys com or nes quotes energy invensys com Network management On box management Network management begins with the device The BayStack 460 Switch supports four groups of Remote Monitoring RMON on all ports and is SNMPv3 compliant T...

Страница 6: ...er specific service offerings which can be implemented to address specific and unique customer requirements Queuing function The BayStack 460 Switch provides network availability for mission critical applications devices and users This is done by classifying prioritizing and marking LAN IP traffic using up to eight hardware based IP service class queues on the Gigabit uplink ports based on the fol...

Страница 7: ...ng of different levels of service by limiting traffic throughput at the ingress incoming port of the BayStack 460 Switch For example if a port is set to certain speeds such as 10 Mbps all traffic under 10 Mbps on that port will pass and traffic that exceeds 10 Mbps on that same port is dropped Service providers will find this especially useful to control bandwidth to their customers IP traffic sha...

Страница 8: ...ltimode 550m 1805 ft fiber optic cable The BayStack 450 1GBIC MDA supports the following GBICs 1000BASE SX Uses shortwave 850 nm fiber optic connectors to connect devices over multimode 550 m or 1 805 ft fiber optic cable 1000BASE LX Uses longwave 1 300 nm fiber optic connectors to connect devices over single mode 5 km or 3 1 mi or multimode 550 m or 1 805 ft fiber optic cable 1000BASE XD Uses sin...

Страница 9: ...dity 95 maximum relative humidity non condensing Operating altitude Up to 3024 m 10 000 ft Storage altitude Up to 3024 m 10 000 ft Safety agency approvals UL listed UL 60950 CUL CAN CSA 22 2 No 60950 CB certificate and report with all national deviations IEC 60950 EN60950 Electromagnetic emissions summary Meets the following standards United States FCC CFR47 PART 15 SUBPART B Class A Canada ICES 0...

Страница 10: ...or GBIC 1550nm Wavelength 40km LC connector AA1419030 1 port 1000BASE CWDM Small Form Factor GBIC 1570nm Wavelength 40km LC connector AA1419031 1 port 1000BASE CWDM Small Form Factor GBIC 1590nm Wavelength 40km LC connector AA1419032 1 port 1000BASE CWDM Small Form Factor GBIC 1610nm Wavelength 40km LC connector AA1419033 1 port 1000BASE CWDM Small Form Factor GBIC 1470nm Wavelength 70km LC connec...

Страница 11: ... 800 4 NORTEL or 1 800 466 7835 from anywhere in North America Nortel Networks the Nortel Networks logo and the globemark design are trademarks of Nortel Networks All other trademarks are the property of their owners Copyright 2003 Nortel Networks All rights reserved Information in this document is subject to change without notice Nortel Networks assumes no responsibility for any errors that may a...

Отзывы: