COOLING AIRFLOW (CFM)
MODEL NAME/
HEATING INPUT
RETURN
AIR VIA:
MOTOR
SPEED
TAP
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
-100U-T35C*
100,000
Btuh Input
95,000
Btuh Output
Bottom
Only
9
2,250
2,250
2,190
2,130
2,080
2,025
1,975
1,915
8
2,055
2,010
1,970
1,900
1,840
1,790
1,730
1,675
7
1,900
1,845
1,795
1,750
1,700
1,650
1,575
1,520
6 *
1,850
1,790
1,745
1,700
1,650
1,595
1,535
1,470
5 **
1,745
1,690
1,645
1,590
1,535
1,485
1,420
1,365
4
1,480
1,420
1,360
1,300
1,230
1,165
1,110
1,055
3
1,315
1,245
1,170
1,100
1,025
975
915
860
2
1,140
1,055
975
890
820
765
705
660
1 ***
1,025
920
830
745
690
625
580
500
Side
Only
9
2,155
2,110
2,075
2,020
1,975
1,965
1,950
1,900
8
1,980
1,940
1,890
1,850
1,805
1,760
1,710
1,650
7
1,835
1,785
1,740
1,685
1,635
1,585
1,545
1,495
6 *
1,785
1,740
1,690
1,640
1,590
1,540
1,490
1,440
5 **
1,690
1,640
1,595
1,540
1,490
1,440
1,390
1,340
4
1,435
1,375
1,300
1,250
1,195
1,140
1,080
1,020
3
1,265
1,190
1,140
1,070
1,005
935
875
815
2
1,095
1,015
945
870
790
715
665
615
1 ***
980
905
835
740
665
590
525
440
Bottom
+
Side
9
2,245
2,195
2,155
2,095
2,065
2,070
2,015
1,950
8
2,080
2,030
1,980
1,930
1,880
1,820
1,765
1,705
7
1,915
1,875
1,820
1,765
1,715
1,655
1,600
1,535
6 *
1,865
1,810
1,755
1,695
1,645
1,585
1,530
1,485
5 **
1,760
1,705
1,655
1,595
1,535
1,480
1,430
1,370
4
1,495
1,430
1,365
1,290
1,235
1,170
1,115
1,065
3
1,325
1,245
1,175
1,095
1,035
970
910
855
2
1,175
1,065
965
900
810
775
705
635
1 ***
1,040
930
850
750
680
610
560
475
*NOTES:
1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
2. Data is shown without filter.
3. Temperature rises in the table are approximate. Actual temperature rises may vary.
4. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
5. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
* Denotes the factory (default) COOL setting.
** Denotes the factory (default) HEAT setting.
** Denotes the factory (default) FAN setting. If an alternate speed is to be used, refer to the installation instructions for Speed Tap Selection.
Table 10. *SD 100U-35EC Blower Data (Cooling Airflow)