Drain hose should be as short as possible with sloping gradient should at least 1/100 to
prevent the formation of air bubble.
◆
If drain hose cannot have sufficient slope, a drain raising pipe should be added.
◆
To prevent drooping of the drain hose, the distance between hoisting stand should be 1 to
1.5m (3 to 5 ft).
1-1.5M
(3-5 ft)
Fig. 6
◆
Use the drain hose and clamp included. Insert the drain hose to the drain vent, and then
tighten the clamp.
◆
Wrap the big sponge on the clamp of drain hose to insulate heat.
◆
Heat insulation should be applied to indoor drain hose.
Sponge(attachment)
Clamp(attachment)
Clamp
Drain hose
Sponge (gray)
<4mm
(1/8 in)
Fig. 7
Drain Setup Pipe Note
◆
The installation height of the drain raising pipe should less than 280mm (11 in).
◆
The drain raising pipe should form a right angle with the unit, and distance to unit should not
beyond 300mm (12 in).
<300mm (12 in)
1-1.5M
(3-5 ft)
<280mm (11 in)
220mm (8-11/16 in)
<500mm
(20 in)
Fig. 8