17
Finish Flange
The finish flange must be installed to vent the combustion
air pipe through the top of the furnace.
NOTE
: For proper
installation it is important that the pipe and screw holes in the
finish flanges, gasket, and cabinet are aligned. See
.
1. Position flange gasket over hole in the furnace cabinet.
2. Position finish flange on top of the flange gasket.
NOTE
: Make sure the flange is properly oriented so that
the FRONT lettering is located near the front of the furnace
as shown in
3. Secure flange and gasket to cabinet with three field supplied
sheet metal screws.
Rubber Grommets
The 2 1/4” rubber grommet is used to seal the opening between
the furnace cabinet and the 2” PVC vent pipe. The rubber
grommet should be installed in the 3” hole prior to running
the vent pipe out of cabinet. No sealants are required. See
The 7/8” rubber grommet is used to seal the opening between
the furnace cabinet and the gas pipe. The rubber grommet
Figure 14. Pressure Switch Tubing
for *SC038 Furnaces Only
Figure 15. Pressure Switch Tubing for
Upflow Furnaces
Models *SC054, *SC072, *SC090, *SC108, & *SC120
Models *SD038, *SD054, *SD072, *SD090, *SD108, & *SD120
Figure 16. Pressure Switch Tubing for
Downflow Furnaces
Models *SL072, *SM054, *SM072, & *SM090
Figure 17. Alternate Pressure Switch Location
PRIMARY
LOCATION
ALTERNATE
LOCATION
Figure 18. Finish Flange
Finish
Flange
Flange
Gasket
Hole for
Flue
Vent Pipe
Hole for Inlet
Air Vent Pipe
FRONT
FRONT lettering must be
located near front
of furnace