background image

Doc No. 702070  Page 4 of 8 

 

ACM900SE6 

ACM1200SE7 

ACM1500SE9 

ACM900SA 

ACM1200SA 

ACM1500SA 

 General Data 

Minimum height 

2.3 

Door width 

mm 

900 

1200 

1500 

900 

1200 

1500 

Heat medium 

 

Electrically heated 

Ambient 

Maximum heat capacity 

kW 

6.0 

7.0 

9.0 

N/A 

Heat setting 

 

1 1 1 

N/A 

Fan type 

Crossflow 

Fan settings 

 

 

Air outlet 

Fixed vent 

Switching type 

Fascia mounted/infrared remote control 

Weight kg 

21.4 

23.2 

25.5 

15.6 

19.5 

25.3 

 Electrical Data 

Supply voltage 

 

                380-415v 3ph 50Hz 

 

                230v 1ph 50Hz 

Total load 

watts 

6160 

7230 

9300 

160 

230 

300 

External fuse/mcb size 

amps 

10 

16 

20 

 Air Data 

Air velocity 

m/s 

 11(HI)  9(LO)  

Noise level 

dB 

55 

56 

57 

 HI  64 
 LO 62 

 HI  67 
 LO 64 

 HI 69 
LO 66 

Air volume 

m³/h 

1220 

1710 

2230 

1220 

1710 

2230 

 Dimensional data

 

Length mm 

900 

1200 

1500 

900 

1200 

1500 

Depth (including bracket) 

mm 

183 

Height mm 

220 

3. Technical Specification. 

4. Internal Wiring Diagrams. 

Fig.2 SA (ambient models) 

Colours may vary 

M

B/S

B/S

B/S

WHITE

BLACK

RED

BLACK

BLACK

BLACK

WHITE

GREEN

RELAY BOARD

BROWN

BLUE

GREEN/YELLOW

B/S

B/S

3 CORE FLEX

5 CORE RIBBON CABLE

I/R RE

ON/OFF SWITCH

B/S

= BUTT SPLICE

FAN

MOTOR

GREEN

BLUE

230v 50Hz 1ph

SUPPLY

B/S

B/S

Содержание AIRBLOC ACM900SE6

Страница 1: ...petent person in accordance with the requirements of the Codes of Practice or the rules in force 2 All external wiring MUST comply with the current IEE wiring regulations 3 Warning this appliance must...

Страница 2: ...annually The manufacturer offers a maintenance service Details are available on request Electrical This unit is suitable for connection to 230 240v SA models 380 415v SE models 50Hz AC supplies The u...

Страница 3: ...ns Model A L1 L2 ACM900SA 900 270 300 ACM900SE6 900 270 300 ACM1200SA 1200 420 300 ACM1200SE7 1200 420 300 ACM1500SA 1500 570 300 ACM1500SE9 1500 570 300 L1 L2 L1 100 8 30 38 A 170 220 13 Fig 1 Mounti...

Страница 4: ...z 230v 1ph 50Hz Total load watts 6160 7230 9300 160 230 300 External fuse mcb size amps 10 16 20 2 4 4 Air Data Air velocity m s 7 11 HI 9 LO Noise level dB 55 56 57 HI 64 LO 62 HI 67 LO 64 HI 69 LO 6...

Страница 5: ...ovide coverage for an invalid doorway width up to 1200mm and an ACM1500SE9 SA unit is suitable for door widths up to 1 5m wide Units can be interlinked 5 Installation Details Fig 4 across wider entran...

Страница 6: ...FF button once more b Front panel operation To turn the unit on press the FRONT PANEL BUTTON once This will start the fan in high speed To change the fan to low speed press the FRONT PANEL BUTTON agai...

Страница 7: ...invalidate warranty ALWAYS ENSURE ELECTRICAL POWER IS SWITCHED OFF BEFORE COMMENCING ANY SERVICING WORK ON THIS AIR CURTAIN 7 Maintenance ALWAYS ENSURE ELECTRICAL POWER IS SWITCHED OFF BEFORE COMMENC...

Страница 8: ...product innovation Nortek Global HVAC reserves the right to change product speci cation without due notice NORTEK GLOBAL HVAC UK LTD Fens Pool Avenue Brierley Hill West Midlands DY5 1QA United Kingdo...