2
Copyright © 2019 Nortek Security & Control LLC
Legacy Smoke Detectors
All Smoke detectors should be replaced after 10 years. If you encounter a smoke
detector that does not support Temporal 3 pattern, that smoke detector should
be replaced as per the manufacturer recommendation. If replacement is not an
option, the FireFighter can be programmed to detect non-temporal detectors.
In this mode, the FireFighter must not be located near any other audible device,
like a security keypad or sounder. Those can be misconstrued as a valid smoke
alarm.
To enter this mode, press and hold the tamper switch while inserting the
battery. Release the tamper switch and note the LED. Repeating this action will
switch the FireFighter operating mode from one to the other.
You can verify the mode FireFighter is in by simply removing the battery and
replacing it. The LED will flash once or twice depending on the mode it is in.
ONE flash: Only Temporal 3 and 4 signal will trigger an alarm (Default).
TWO flashes: Generic listening mode. Will trigger after 30 seconds of continuous
sounding.
REPLACING THE BATTERY
When the battery is low a signal will be sent to the control panel. To replace the
battery:
1.
Slide Sensor in direction of arrow to remove from mounting plate. (See Image 6).
2. Remove 2 screws from sensor base. Remove the top cover to reveal the
battery. This will send a tamper signal to the control panel.
3.
Replace with a Panasonic CR123A battery ensuring the + side of the battery
faces as indicated on the device.(See Image 1).
4.
Re-attach the cover, you should hear a click when the cover engages properly.
Re-install the two screws holding the sensor together.
WARNING: While the audio detector monitors its own battery,
it does not monitor the battery in the smoke detectors. Batteries
should be changed as per the original smoke detector manufacturer’s
instructions. Always test the audio detector and smoke alarms after
battery installation to confirm proper operation.
Specifications
Transmitter Frequency
345.00 MHz
(crystal controlled)
Battery
One 3Vdc lithium
CR123A (1550 mAh)
Code Outputs
Alarm; Supervisory; Low Battery
Battery Life
3 Years
Detection distance
6 inches max
Operating Temperature
32° to 120° F (0° to 49° C)
Operating Humidity
5-95% RH non-condensing
Compatibility
2GIG Control Panel
Supervisory Interval
64 min (approx.)
Maximum current draw
23mA during transmission
Housing Material
ABS Plastic
Color
White
Regulatory Listings
FCC, IC
Equipment Code
2069
Regulatory Information
We, Nortek Security & Control, LLC of 5919 Sea Otter Place STE 100, Carlsbad, CA 92010,
declare under our sole responsibility that the device, 2GIG-FF1E-345 complies with Part 15
of the FCC rules.
FCC & IC Notice
TThis device complies with Part 15 of the FCC Rules and Industry Canada license exempt
standard(s). Operation is subject to the following two conditions:
(1)
This device may not cause harmful interference, and
(2)
This device must accept any interference received, including interference received
that may cause undesired operation.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
(1)
l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si
le brouillage est susceptible d’en compromettre le fonctionnement.
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver
•
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected
•
Consult the dealer or an experienced radio/TV technician to help.
WARNING
Changes or modifications not expressly approved by the manufacturer could void the user’s
authority to operate the equipment.
* For more warranty and compliance information, visit out website (
www.2gig.com
)
Limited Warranty
This Nortek Security & Control product is warranted against defects in material and workmanship
for two (2) years.
This warranty extends only to wholesale customers
who buy direct from Nortek
Security & Control LLC or through Nortek Security & Control LLC’s normal distribution channels.
Nortek Security & Control LLC does not warrant this product to consumers.
Consumers should
inquire from their selling dealer as to the nature of the dealer’s warranty, if any.
There are no
obligations or liabilities on the part of Nortek Security & Control LLC for consequential damages
arising out of or in connection with use or performance of this product or other indirect
damages with respect to loss of property, revenue, or profit, or cost of removal, installation,
or reinstallation.
All implied warranties for functionality, are valid only until the warranty expires.
This Nortek Security & Control LLC Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Authorization Number (RA#). Contact
Returns at 1-855-546-3351 for an RA# and other important details.
Disclaimer
The Firefighter sensor does not detect the presence of smoke, heat, or fire directly. It relies
solely on the presence of an audio alarm signal generated by an existing smoke or fire detector
in proximity to the Firefighter sensor to make such a determination. The Firefighter™ sensor
must be used with smoke detectors certified according to UL Standards, and in strict accordance
with the installation and operation instructions provided with such detectors. It is the owner’s
responsibility to ensure that smoke or fire detectors used in conjunction with the Firefighter
sensor are maintained and tested on a regular basis in accordance with the manufacturer’s
instructions. Nortek Security and Control expressly disclaims any responsibility for the failure of
the Firefighter sensor to detect the presence of smoke or fire due to the failure of any smoke
or fire detector used in conjunction with the Firefighter sensor to operate properly due to any
condition, including improper installation, operation, maintenance or testing of such smoke or
fire detector.
2GIG-FF1E-345 Installation Instructions
10024471 B
SENSOR MOUNTING PLATE
MOUNTED TO CEILING
SLIDE SENSOR
IN DIRECTION OF
ARROW TO REMOVE
FROM MOUNTING PLATE
Image 6
Nortek Security & Control LLC | 2GIG
5919 Sea Otter Place, Suite 100
Carlsbad, Ca. 92010
For technical support in the USA and Canada:
855‐2GIG‐TECH (855‐244‐4832)
Email:
Visit
www.nortekcontrol.com
for technical support hours of operation
For technical support outside of the USA and Canada:
Contact your regional distributor
Visit
www.dealer.2gig.com
for a list of distributors in your region