4.0  INSTALLATION - REFLECTOR BAFFLES

4.1 

REFLECTOR  BAFFLES  (T2D  units  only).

Refer  to  Figure  1  when  installing  reflector 

baffles.

 

FIGURE 1 - REFLECTOR BAFFLES INSTALLATION

 

TABLE 1 - 

REFLECTOR BAFFLE PAIRS PER HEAT SINK

Heat Sink Extrusion 

Length

# of Pairs

Size

in

mm

in

mm

5.1

130

0

-

-

11.8

300

1

8

203

18.5

470

2

8

203

25.2

640

1

24

610

 

NOTE:

 Baffles are only required for units with a T2D 

temperature code rating.

4.2 

Position  heater  front  face  down  on  a  flat 

surface.

4.3 

With the fold in the baffle positioned between 

the keyhole fin and the adjacent short fin, slide 

reflector baffles onto the back of heat sink.

4.4 

Ensure  reflector  baffles  are  secure  in  place 

and  flush  with  the  top  of  the  heat  sink.  If 

reflector  baffles  move  freely,  open  the  fold 

with a screw driver to improve the friction and 

reinstall baffles.

CAUTION

THE HEATERS SURFACE IS HOT WHEN 

THE HEATER IS ENERGIZED. KEEP ALL 

COMBUSTIBLES AWAY FROM THE HEATER 

AND MAINTAIN THE RECOMMENDED 

INSTALLATION CLEARANCES AT ALL TIMES.

 

FIGURE 2 - DIMENSIONS & MOUNTING DETAILS

TABLE 2 - 

HEATER DIMENSIONS

Unit

in (mm)

in (mm)

in (mm)

in (mm) in (mm)

in (mm)

XB1

7.250 

(184)

10.250 (260) 9.625 (244)

-

-

5.125 (130)

XB1

17.000 (432) 16.375 (416)

11.875 (300)

XB1

23.625 (600) 23.000 (584)

18.500 (471)

XB1

30.375 (772) 29.750 (756)

25.250 (640)

XB2

16.125 

(410)

10.250 (260) 9.625 (244)

7.125 

(181)

8.250 

(210)

5.125 (130)

XB2

17.000 (432) 16.375 (416)

11.875 (300)

XB2

23.625 (600) 23.000 (584)

18.500 (471)

XB2

30.375 (772) 29.750 (756)

15.250 (640)

XB3

25.000 

(635)

10.250 (260) 9.625 (244)

13.750 

(349)

17.125 

(435)

5.125 (130)

XB3

17.000 (432) 16.375 (416)

11.875 (300)

XB3

23.625 (600) 23.000 (584)

18.500 (471)

XB3

30.375 (772) 29.750 (756)

15.250 (640)

XB4

33.875 

(860)

10.250 (260) 9.625 (244)

22.625 

(575)

26.000 

(664)

5.125 (130)

XB4

17.000 (432) 16.375 (416)

11.875 (300)

XB4

23.625 (600) 23.000 (584)

18.500 (471)

XB4

30.375 (772) 29.750 (756)

15.250 (640)

Содержание XB1

Страница 1: ...codes WARNING DO NOT CONNECT THE HEATER TO AN ELECTRICAL SUPPLY VOLTAGE OTHER THAN THAT SHOWN ON THE PRODUCT NAMEPLATE 3 0 INSTALLATION GENERAL REQUIREMENTS 3 1 NorsemanTM XB heaters are approved for wall or floor mounting with the terminal housing at the bottom Ensure that is the wall sufficiently strong to support the heater which depending on the model could weigh up to 100 lbs 45 kg Otherwise ...

Страница 2: ...nstall baffles CAUTION THE HEATERS SURFACE IS HOT WHEN THE HEATER IS ENERGIZED KEEP ALL COMBUSTIBLES AWAY FROM THE HEATER AND MAINTAIN THE RECOMMENDED INSTALLATIONCLEARANCESATALLTIMES FIGURE 2 DIMENSIONS MOUNTING DETAILS Table 2 HEATER DIMENSIONS Unit B F G M N L in mm in mm in mm in mm in mm in mm XB1 7 250 184 10 250 260 9 625 244 5 125 130 XB1 17 000 432 16 375 416 11 875 300 XB1 23 625 600 23 ...

Страница 3: ...kets with supplied 1 4 20 hex bolts and lock washers Figure 5 FIGURE 5 ATTACH HEATER TO MOUNTING BRACKETS 6 0 FLOOR MOUNTING Step 1 Position heater face down on the floor with terminal box towards the wall Figure 6 FIGURE 6 FLOOR MOUNTING DIAGRAM Step 2 Fasten top stabilizing bracket s and floor mounting bracket s to the unit Floor mounting brackets may be mounted in one of three orientations Figu...

Страница 4: ...C 8 3 Use approved conduit and conduit seals as required by the code for hazardous locations 8 4 To provide maximum protection each NorsemanTM XB heater should be fused individually using the nearest standard fuse size which is not less than 120 of the expected line current 8 5 All heaters come factory prewired and ready for direct connection to the power supply leads a Connect the power leads to ...

Страница 5: ...TER DO NOT EXCEED THE MAXIMUM ALLOWABLE AMBIENT OPERATING TEMPERATURE OF 104 F 40 C 10 0 MAINTENANCE 10 1 Periodically inspect the heater installation to ensure that all connections fittings plugs screws covers etc are tight and free of corrosion 10 2 Check that the reflector baffles if required have not moved upwards or downwards in relation to the heat sink 10 3 Check the extrusions of the heate...

Страница 6: ...6 NOTES ...

Страница 7: ...7 NOTES ...

Страница 8: ... of parts No warranty applies to paint finishes except for manufacturing defects apparent within 30 days from the date of installation The Company neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the product s The Purchaser agrees that all warranty work required after the initial commissioning of the product will be provided only if th...

Отзывы: