© Norsat International Inc.
(“Norsat”) All Rights Reserved
2022-04-04 908236 Rev C
29
3.2 Fans & Baseplate Cooling
The standard ATOM configuration employs an integrated radiator and IP55 fans to cool the unit. A minimum
clearance of 1 inch must be maintained around the air intake and exhaust during use. The fans are a field
replaceable assembly; contact Norsat for details on replacement kits. If the unit is deployed inside a
radome, ensure there is adequate cooling to remove heat and prevent the unit from overheating.
The ATOM is also available with a flat plate in place of the radiators and fans. It is the user’s responsibility
to ensure that the plate the unit is mounted to is capable of rejecting any heat produced by the unit. Please
contact Norsat for cooling requirement specifications.
3.3 Accessories
Each ATOM unit ships with mating connectors for the both M&C Port and the Power Port connectors as
well as hardware for the waveguide flange and ground terminal. No hardware is provided to mount the unit.
A range of optional accessories such as pre-built power cables, M&C test cables, and M&C signal adaptors
are also available; please contact Norsat for details.
3.4 General Specifications
: General 80W ATOM Specifications
summarizes general specifications applicable to most
80W ATOM units. Please refer to the specific ATOM datasheet available on the Norsat website for complete
unit specifications.
Table 3-1: General 80W ATOM Specifications
Parameter
Specifications
RF Power Output (P1dB)
80W *
Gain (min)
60dB *
Operating Temperature with fans
-40°C to +60°C
Storage Temperature
-54°C to +80°C
Thermal Shutdown Temperature
90°C ±3°C
Weight
6.9kg (15.3lbs) #
Input Voltage (DC)
20 to 56 VDC
Input Voltage (3-Phase AC Only)
208VAC, 60-
400Hz
Power Consumption, DC BUC unit with fan
(PSAT)
540W
* Frequency dependent, 80W DC BUC over 13.75-14.5GHz range
# Configuration dependent