27
Ethernet Method (alternate method)
5.
Connect the ATOM’s Ethernet port directly to a computer running Microsoft Windows and power
on the ATOM.
6. Disable any wireless connections (if present).
7. Launch a command prompt window (
Start
>
Run
>
cmd
)
8. Type in the following command and press the carriage return key:
Tx:
arp
–
a <cr>
9. A list of all Ethernet devices connected to the computer will be displayed. In this case, the ATOM
Ethernet web server should be the only device listed in the summary.
10. Follow the instructions in the preceding section to restore the IP Address to the desired setting.
2.5 J4
– RF Output
The RF output port is either WR75 (standard) or WR62 (optional/frequency dependent) square waveguide
flange. The unit is supplied with two screw lengths (four 6-32x3/8" and four 6-
32x7/16"); it is the user’s
responsibility to ensure that the appropriate screw length is used. There should be at least 4 threads of
engagement (0.125") with the holes in the waveguide flange.
The waveguide output port should not be relied upon to act as a mechanical support for the unit. Refer to
Appendix A for the size and position of the ATOM mounting holes.
2.6 Ground Connection
The unit is supplied with a #10-32 screw and internal tooth lock washers for grounding purposes. It is highly
recommended that the unit be grounded according to national and local electrical codes by skilled person
before use.
2.7 Indicators / LEDs
There are three LEDs on the unit that indicate the unit status to the user.