Rev. 2.0
7005STC-O3B Series
DES007565
______________________________________________________________________________________
25
window.
3) When Over-power became red on the BUC GUI window.
•
IF input power is too high
o
Check the IF input power level.
•
Or, the BUC is faulty
o
Contact Norsat International for further support.
4) When External Mute became red on the BUC GUI window.
•
External Mute pin is not connected to ground.
o
Check the External Mute wire being connected to ground.
•
Or, the BUC is faulty
o
Contact Norsat International for further support
B) RF output power is low even if SSPA is on
1) Gain setting on the BUC GUI window is too low
•
Check gain setting on the BUC GUI.
2) Input IF power is too low to drive the BUC properly
•
Check the output level of the IF power source.
3) IF cable or connectors has high insertion loss
•
Check the IF cable or connectors.
4) RF cable or connector or WR28 waveguide adapter has high insertion loss
•
Check the RF cable, connector, or WR28 waveguide adapter.
5) One of internal components are faulty
•
Contact Norsat International for further support.
7. WARRANTY AND SERVICE INFORMATION
All the equipment (BUC) supplied or manufactured fulfils the following warranty conditions except
when other conditions are specified at the moment of purchasing.
Warranty limit:
The seller guarantees that every item supplied by the manufacturer is free of
mistakes or human manipulation. This warranty is not applied to those materials or components that
are not supplied by the manufacturer or those that have been exposed to possible damaging
situations or those that are not manipulated under the security conditions described in the user
manual.
The standard length of the warranty is two (2) years, except if otherwise established at the time of
purchase.
Repair conditions:
Items returned will be tested to determine the fault in the equipment, and the best
repair procedure. The replacement or return will be established once the manufacturer has determined
the cause of the fault. All the equipment returned is subject to a charge for its evaluation when the
warranty cover is not applicable for any reason or when the client authorizes the repair out of warranty.
Remember that if a failure in the equipment is not found the client will be the responsible for paying the