background image

TROUBLESHOOTING 

Before requesting any service on your unit, please check the following points:

 

1.

Check the water supply: 

Verify that there is water in the water trough.

Make sure the water pressure is between 1.3-5.5 bar, and the water temperature is between 41-95°F (5-35°C). 

Make sure the water valve is open and there are no leaks.

2.

Check the power supply:

Check the display to verify that that unit is turned on. 

Verify that power to the outlet is on, that the outlet is good, and the plug is properly connected.

Use the following table to try to diagnose common issues. Please note that this guide serves only as a reference for solutions to common problems. If a 
service call is needed, be sure to obtain the model and serial number before calling customer service. 

Symptom

 

Possible Cause

 

Corrective Action

 

Not working

 

Power switch not on

 

Turn on the power switch

 

Plug is loose

 

Verify plug is securely connected to a working outlet 

Indicator is ‘Off’

 

Power switch not on

 

Turn on the power switch

 

Plug is loose

 

Verify plug is securely connected to a working outlet 

Display shows ‘E04’ high 
temperature error code 

The ambient temperature is too high

 

Make sure the unit is installed somewhere with an 
ambient temperature of 41-104°F (5-40°C)

 

Condenser is dirty or blocked

 

Clean the condenser and make sure nothing is blocking 
air flow 

Fan is not running

 

Make sure nothing is blocking the fan from 
running. 

Display shows ‘E06’ High pressure error 
code 

High pressure switch wires disconnected

 

Check and connect the wires on the high 
pressure switch 

Not defrosting

 

Ambient temperature too low

 

Make sure the unit is installed somewhere with an 
ambient temperature of 41-104°F (5-40°C) 

Defrost valve does not start normally

 

Check the defrost valve, correct issues if found 

Ice is too thin or too thick

 

Check the ice thickness setting

 

Poor transparency of ice cubes; ice 
cubes too thin or incomplete

 

Ice thickness too thin 

Check the ice thickness setting

 

Water pressure too low

 

Verify that the water supply pressure is 1.3 Bar to 
5.5 Bar 

Water temperature too high

 

Make sure the water temperature is between 41-95°F 
(5-35°C)

Water inlet valve does not work

 

Check the water inlet valve and correct any issues 

Water leaking

 

Check all water connections and tighten as needed 

Water inlet filter has not been replaced for a long time 

Replace the filter

 

Ice making process too slow

 

Condenser or air filter is dirty

 

Clean the condenser and filter or replace filter

 

Ambient temperature too high

 

Make sure the unit is installed somewhere with an 
ambient temperature of 41-104°F (5-40°C) 

Not enough ventilation air flow

 

Make sure there is adequate space around unit 

 

Water temperature too high

 

Make sure the water temperature is between 41-95°F 
(5-35°C)

Making noise

 

Unit is not level or on a level surface

 

Make sure unit is correctly installed and leveled 

14

Содержание NPCIM120H

Страница 1: ...POLE Commercial Undercounter Ice Maker User s Manual READ THIS MANUAL CAREFULLY BEFORE USING YOUR COMMERCIAL ICE MAKER AND KEEP IT FOR FUTURE REFERENCE Models NPCIM90B NPCIM120H NPCIM160H NPCIM210 NPCIM280 ...

Страница 2: ...s of registering your product include the following 1 Registering your product will allow us to contact you regarding a safety notification or product update 2 Registering your product will allow for more efficient warranty service processing when warranty service is required 3 Registering your product could act as your proof of purchase in the event of insurance loss Once again thank you for purc...

Страница 3: ...F CONTENTS REGISTRATION 2 IMPORTANT INFORMATION 4 IMPORANT SAFETY INSTRUCTIONS 5 SPECIFICATIONS 7 INSTALLATION INSTRUCTIONS 8 OPERATION INSTRUCTIONS 10 CARE AND MAINTENANCE 12 TROUBLESHOOTING 14 WARRANTY 16 3 ...

Страница 4: ...used There is a risk of fire The label indicates a hazardous voltage There is a risk of electric shock The label indicates a flammable refrigerant R290 used There is a risk of fire The label indicates rotating components inside There is a risk of serious mechanical injury Instruction of symbols in this Manual Warning sign special attention is required Warning sign special attention is required and...

Страница 5: ...cut the power cord or use any other cord or plug DO NOT use an extension cord 12 This appliance should not be operated by anyone that is not able to follow proper safety procedures or does not have experience with this type of equipment unless under close supervision Keep children away from the device 13 DO NOT allow children to play in or on the ice maker 14 WARNING DO NOT store anything flammabl...

Страница 6: ...OF FIRE OR EXPLOSION DISPOSE OF PROPERLY IN ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS FLAMMABLE REFRIGERANT USED CAUTION RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING FOLLOW HANDLING INSTRUCTIONS CAREFULLY FLAMMABLE REFRIGERANT USED General The ice machine is fully automatic With proper installation and connection to potable water and power source the ice making will start pro...

Страница 7: ...2 660 x 685 x 970 mm 121 3 lbs 55 kg Figure 1 Model NPCIM90B a c b Model NPCIM120H d f e Model NPCIM160H NPCIM210 NPCIM280 g i h 26 0 x 27 0 x 38 2 660 x 685 x 970 mm 26 0 x 27 0 x 38 2 660 x 685 x 970 mm 120 lbs 54 kg 24 hr 160 lbs 73 kg 24 hr 210 lbs 95 kg 24 hr 280 lbs 127 kg 24 hr 40 lbs 18 kg 80 lbs 36 kg 80 lbs 36 kg 80 lbs 36 kg 127 9 lbs 58 kg 132 3 lbs 60 kg a 30 0 762mm b 14 8 375mm c 22...

Страница 8: ...achine should be kept away from heat sources and should not be used in an extremely high or low temperature environment and away from direct sunlight The ice machine must be placed on a floor sufficient to support its weight when filled with water or ice The electrical outlet for the ice maker must be properly grounded and with leakage protection Proper floor drainage must be provided near the ins...

Страница 9: ...nt and floor cleaning Use these to make sure the ice maker is level 7 Connect the machine s inlet water filter and water pipe referring to the schematic diagram of installation if the installation site is already equipped with a water filtration system the filter may not be needed NOTE Make sure to install the filter so the water is flowing in the direction noted on the filter head cover or filter...

Страница 10: ...ss the ice maker is in c Ice Cube Thickness adjustment During the ice making process press and hold the button for 3 seconds then press or to change the thickness of the ice being made NOTE Pushing the or button extends or shortens the ice making time by 1 5 minutes d Cleaning During operation press the cleaning button for 3 seconds to start the cleaning process As the display shows the steps of t...

Страница 11: ... running normally and there is stable air flow in the inlet and outlet of the ice machine There are no abnormal noises or vibrations It takes about 10 to 20 minutes to make one batch ice depending on the ambient temperature and the temperature of the water The higher the temperature is the longer the ice making will take When you turn the power switch On the unit will run a self check and pump any...

Страница 12: ...th a brush to brush it up and down along the fin direction to avoid damage to the fins and further affecting the cooling effect The condenser filter should be removed and carefully cleaned every 2 weeks NOTE Be careful when doing the condenser cleaning as the edges of the fins are sharp INLET WATER FILTER The filter should be inspected regularly and replaced every 1 3 months based on usage and wat...

Страница 13: ...ization solution into the water trough per the product instructions and press the Clean button again The process will run about 15 minutes Be sure to spray some of the solution onto the evaporator while this is running to ensure complete sterilization When sterilization is complete the unit will enter a rinsing cycle that lasts about 5 minutes This will repeat 5 times When the entire cleaning cycl...

Страница 14: ...g air flow Fan is not running Make sure nothing is blocking the fan from running Display shows E06 High pressure error code High pressure switch wires disconnected Check and connect the wires on the high pressure switch Not defrosting Ambient temperature too low Make sure the unit is installed somewhere with an ambient temperature of 41 104 F 5 40 C Defrost valve does not start normally Check the ...

Страница 15: ... Sleep mode Unit will recover after water curtain is reset E03 Ice Harvest Overtime Sleep Mode E04 High Temperature Fault Sleep Mode E05 Water Shortage Fault Sleep Mode Unit will retry every 30 minutes E06 Over Pressure Fault Sleep Mode E07 Condenser Temperature Sensor Open Circuit Fault Keep Working E08 Condenser Temperature Sensor Short Circuit Fault Keep Working 15 ...

Страница 16: ...this product if used for purposes other than its intended purpose Disposal costs for any failed unit not returned to our factory Any delivery or installation costs incurred as the result of a unit that fails to perform as specified Expenses for travel and transportation for product service if your appliance is located in a remote area where service by an authorized service technician is not availa...

Страница 17: ... de hielo comercial bajo mostrador Manual del usuario LEA ATENTAMENTE ESTE MANUAL ANTES DE USAR LA MÁQUINA DE HIELO COMERCIAL Y CONSÉRVELO PARA FUTURAS REFERENCIAS Modelo NPCIM90B NPCIM120H NPCIM160H NPCIM210 NPCIM280 ...

Страница 18: ... registrar este producto 1 El registro del producto nos permitirá contactarlo con relación a un aviso de seguridad o actualización del producto 2 El registro del producto nos permitirá procesar con más eficiencia el servicio de garantía cuando este servicio sea requerido 3 El registro del producto puede servir como prueba de compra en el caso de pérdida cubierta por el seguro Una vez más gracias p...

Страница 19: ... 18 INFORMACIÓN IMPORTANTE 20 INSTRUCCIONES DE SEGURIDAD IMPORTANTES 21 ESPECIFICACIONES 23 INSTRUCCIONES DE INSTALACIÓN 24 INSTRUCCIONES DE OPERACIÓN 26 CUIDADO Y MANTENIMIENTO 28 SOLUCIÓN DE PROBLEMAS 30 GARANTÍA 32 19 ...

Страница 20: ...esgo de incendio La etiqueta indica tensión peligrosa Riesgo de descarga eléctrica La etiqueta indica que se usa el refrigerante inflamable R290 Riesgo de incendio La etiqueta indica componentes giratorios en el interior Riesgo de lesiones mecánicas graves Instrucción de los símbolos en este manual Signo de advertencia es necesario prestar especial atención Signo de advertencia es necesario presta...

Страница 21: ...ica y otros datos técnicos específicos de este equipo 11 NO modifique ni corte el cable de alimentación ni utilice ningún otro cable o enchufe NO utilice un cable de extensión 12 Este aparato no debe ser operado por alguien que no pueda seguir los procedimientos de seguridad adecuados o sin experiencia con este tipo de equipos a menos que sea bajo atenta supervisión Mantenga el dispositivo lejos d...

Страница 22: ...ESGO DE INCENDIO O EXPLOSIÓN ELIMINAR DE FORMA CORRECTA DE CONFORMIDAD CON LAS REGLAMENTACIONES FEDERALES O LOCALES SE HA USADO REFRIGERANTE INFLAMABLE PRECAUCIÓN RIESGO DE INCENDIO O EXPLOSIÓN EN CASO DE PINCHADURAS DE LA TUBERÍA REFRIGERANTE SIGA DETENIDAMENTE LAS INSTRUCCIONES DE MANIPULACIÓN SE UTILIZA REFRIGERANTE INFLAMABLE Generalidades La máquina de hielo es completamente automática Con un...

Страница 23: ...0 x 27 0 x 38 2 660 x 685 x 970 mm 121 3 lbs 55 kg Figure 1 Modelo NPCIM90B a c b Modelo NPCIM120H d f e Modelo NPCIM160H NPCIM210 NPCIM280 g i h 26 0 x 27 0 x 38 2 660 x 685 x 970 mm 26 0 x 27 0 x 38 2 660 x 685 x 970 mm 120 lbs 54 kg 24 hr 160 lbs 73 kg 24 hr 210 lbs 95 kg 24 hr 280 lbs 127 kg 24 hr 40 lbs 18 kg 80 lbs 36 kg 80 lbs 36 kg 80 lbs 36 kg 127 9 lbs 58 kg 132 3 lbs 60 kg a 30 0 762mm ...

Страница 24: ...ionar a una temperatura ambiente de 45 55 F 7 13 C La máquina de hielo debe mantenerse alejada de fuentes de calor y de la luz solar directa además no debe usarse con temperatura ambiente extremadamente alta o baja La máquina de hielo debe colocarse en un piso capaz de soportar su peso cuando está llena con agua o hielo El tomacorriente para la máquina de hielo debe estar bien conectado a tierra y...

Страница 25: ...l y limpiar el piso Úselas para que la máquina de hielo quede nivelada 7 Conecte el filtro de entrada de agua y la manguera de agua de la máquina usando el esquema de conexiones para instalación si el lugar de la instalación ya tiene un equipo de filtrado de agua puede no ser necesario el filtro NOTA Asegúrese de instalar el filtro de modo que el agua fluya en el sentido indicado en la tapa del ca...

Страница 26: ...na de hielo c Ajuste del espesor del cubo de hielo Durante el proceso de fabricación de hielo presione y mantenga presionado el botón durante 3 segundos luego presione o para modificar el espesor del hielo NOTA Presionar el botón o alarga o acorta el tiempo de fabricación de hielo 1 5 minutos d Limpieza Durante la operación presione el botón de limpieza durante 3 segundos para iniciar el proceso d...

Страница 27: ...y que haya un flujo de aire estable en la entrada y salida de la máquina de hielo No hay ruidos ni vibraciones anormales Hacer un lote de hielo demora entre 10 y 20 minutos según la temperatura ambiente y la temperatura del agua Cuanto mayor sea la temperatura más se tardará en hacer el hielo Cuando usted coloca el interruptor de encendido en ON el equipo realizará una autocomprobación y expulsará...

Страница 28: ...o y la calidad del agua TUBERÍA DE AGUA Para asegurar la seguridad de los alimentos se deberá limpiar la tubería de agua con regularidad ALMACENAMIENTO Si el equipo no va a ser usado durante un largo tiempo o será guardado corte el agua y desconecte del suministro eléctrico Limpie el interior y el exterior del equipo y asegúrese de vaciar toda el agua de la tolva la tubería de alimentación y la tu...

Страница 29: ...olución de esterilización en la tolva de agua siguiendo las instrucciones del producto y vuelva a presionar el botón Clean Limpiar El proceso durará unos 15 minutos Asegúrese de pulverizar un poco de solución sobre el evaporador mientras está funcionado para garantizar una completa esterilización Cuando la esterilización haya terminado el equipo pasará a un ciclo de enjuague que dura unos 5 minuto...

Страница 30: ...e El ventilador no funciona Corrobore que nada esté impidiendo el movimiento del ventilador La pantalla muestra el código de error E06 por alta presión Los cables del interruptor por alta presión están desconectados Revise y conecte los cables del interruptor por alta presión No descongela La temperatura ambiente es muy baja Asegúrese de que el equipo esté instalado en algún lugar con una temperat...

Страница 31: ...hielo Modo de suspensión E04 Falla por alta temperatura Modo de suspensión E05 Falla por falta de agua Modo de suspensión El equipo volverá a intentarlo cada 30 minutos E06 Falla de sobrepresión Modo de suspensión E07 Falla del circuito abierto en Sensor de temperatura de condensador Se mantiene en funcionamiento E08 Falla del circuito en corto en Sensor de temperatura de condensador Se mantiene e...

Страница 32: ...roducto si se usa para fines distintos para los que fue diseñado Costos de eliminación de cualquier equipo defectuoso no devuelto a fábrica Ninguno de los costos de entrega o instalación incurridos como resultado de un equipo que no funcione según las especificaciones Gastos de viaje y transporte para el servicio del producto si el electrodoméstico se encuentra en un lugar remoto donde el servicio...

Отзывы: