background image

4. Ensure that the airflow to the condenser unit is not obstructed.

When installing the cabinet, make sure of the following:

• The area where the cabinet is placed is flat and level.
• No objects are placed on top of the cabinet.
• The cabinet is not placed in the immediate vicinity of a heat source such as a radiator,

warm air blowing heater or spotlight. See

figure A

.

• The cabinet is not exposed to direct sunlight. If necessary, use blinds in any nearby

window. See

figure B

.

• The air conditioning for the premises does not blow onto the cabinet. See

figure C

.

The correct positioning of the cabinet optimises temperature conditions and performance.
Cabinets with castors / wheels may be anchored to the wall behind them as a safety

precaution.

2.5. Cleaning before use

1. Clean the cabinet surfaces and the storage compartment for foodstuffs with a mild liquid

detergent (pH 6-8) before using the cabinet.

Follow the instructions provided with the detergent.

Make sure that all cleaning fluids are classed as non-toxic.

NOTE

2. Dry the surfaces carefully.

3. Electrical connections

The symbol marked on the cabinet (a lightning bolt inside a triangle) indicates that

there are components and wires under the cover containing live voltage. Only

personnel qualified to install and service electrical equipment are permitted access

to areas that contain live voltage.

NOTE

Check the voltage and size of the fuse required from the rating plate fixed to the cabinet. The

supply socket must be earthed. Fuse ratings for different types of plugs are presented in the

following table:

4

Version 2/2010

ENGLISH

PI

Содержание EUROCLASSIC

Страница 1: ...USER S GUIDE ...

Страница 2: ...ON OFF min 20 ELECTRIC DIAGRAM FAKTA MANUAL ...

Страница 3: ... Starting up 5 4 2 Loading cabinet 5 4 3 Setting operating thermostat 6 4 4 NRC 100 control device 6 4 4 1 Display messages 6 4 4 2 Checking temperature settings 7 4 5 Automatic defrosting 7 5 Cleaning 7 5 1 Cleaning condenser 8 6 Interruptions in electricity distribution 9 7 Troubleshooting 9 8 Servicing and spare parts 9 8 1 Replacing fluorescent tube 9 9 Disposal of equipment 10 i Version 2 201...

Страница 4: ... does not extend to any breakage of glass accidental or otherwise NOTE 2 EuroClassic Euromax EuroClassic Euromax is a display cabinet for dairy products meat products processed foods salads prepared foods convenience foods fruits vegetables and beverages that maintains the storage temperature required by these products The cabinet can be extended to form long rows of display shelving Cabinets of t...

Страница 5: ...e 2 3 Transport damage Unpack the cabinet and check for any sign of damage during transport Report any damage immediately to your insurance company or to the supplier or manufacturer of the cabinet 2 4 Installing 1 Release the tape from the air gap stopper and let it fall into a horizontal position 2 Set the cabinet in its place Leave an unobstructed air gap of at least 8 cm behind the cabinet als...

Страница 6: ... wall behind them as a safety precaution 2 5 Cleaning before use 1 Clean the cabinet surfaces and the storage compartment for foodstuffs with a mild liquid detergent pH 6 8 before using the cabinet Follow the instructions provided with the detergent Make sure that all cleaning fluids are classed as non toxic NOTE 2 Dry the surfaces carefully 3 Electrical connections The symbol marked on the cabine...

Страница 7: ...em The evaporator is located at the bottom tray or the lower part of the rear wall depending on the version The cold air is blown to the shelves through the perforated back wall and through the cooling cell in the top corner The cabinet is equipped with a NRC 100 controller which turns off the cabinet s lights in case of a pressure rise caused for example by dirt in the condenser See figure 1 on t...

Страница 8: ... in the cabinet NOTE 4 3 Setting operating thermostat The operating thermostat for the cabinet is located in the terminal box inside the machinery compartments The lid to the machinery compartment is fixed with a spring The thermostat is preset to the correct temperature at the factory 4 4 NRC 100 control device NRC 100 is a cabinet controller that automates cabinet defrosting by means of a thermo...

Страница 9: ...n the display 3 Press the FNC key again to return to normal status The normal temperature view also reappears if you do not touch any button for five 5 minutes 4 5 Automatic defrosting The cabinet is equipped with an automatic defrosting device The NRC 100 unit controls the operation periods and the defrosting process Defrosting is performed six 6 times a day electric defrosting Drain water from d...

Страница 10: ...n the service life of the electric heater hot gas piping for the drain sump Detergent residues must be cleaned without delay from the tray NOTE In the event of a refrigerant leakage all products displayed in the cabinet must be disposed of and then the cabinet must be cleaned NOTE 5 1 Cleaning condenser Check once a month or more often if necessary that the condenser is clean Carry out the followi...

Страница 11: ...ical supply to the cabinet and contact the service organisation Check at regular intervals that the operating noise of the cabinet is normal the condenser and evaporator are clean and the air flow through the inlet and outlet grids is not obstructed by debris packaging waste or other such material 8 Servicing and spare parts The specifications of the cabinet are marked on the rating plate see the ...

Страница 12: ...ipment After reaching the end of its service life the cabinet must be disposed of in compliance with local regulations and instructions Seek expert advice when disposing of substances that are harmful to the environment and when utilising recyclable material 10 Version 2 2010 ENGLISH PI ...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ... AB Tel 46 8 594 112 00 www norpe se info norpe se NORWAY Norpe AS Tel 47 33 36 35 00 www norpe no post norpe no POLAND Norpe Polska Sp z o o Tel 48 22 882 00 20 www norpe pl norpe norpe pl RUSSIA Norpe Russia Tel 7 812 273 3912 ESTONIA Norpe Eesti Oü Tel 372 656 1717 www norpe ee info norpe ee LATVIA Norpe Latvia Filiale Tel 371 736 9827 www norpe com info norpe lv 2 10 Subject to alterations wit...

Отзывы: