4
NM 3525 24 Elements antenna system adjustments - LLZ
4.1
Mechanical alignments of antenna array
4.1.1
Right angle points with reference to runway centre line
The alignment of the antenna array perpendicular to the runway centreline should be carried
out to an accuracy of 0.01°.
This corresponds to within 5 mm accuracy at positions antenna 1 and antenna 24. A theodo-
lite should be utilised.
4.1.2
Spacing distance between LPDA’s
Check that the spacing between each LPDA is 2.04 m.
Tolerance: ±5 mm.
4.1.3
Vertical alignment of LPDA support masts
On each rear support mast for LPDA check with waterlevel that mast is vertically aligned in
both planes.
4.1.4
Azimuth alignment of LPDA’s
Determine a fixed point as far as possible along the extended centreline not less than approx-
imately 3000 m from the antenna array.
On each LPDA utilise the top horizontal line composed of the two half sections of the radome
to point toward the fixed point.
If necessary adjust the LPDA horizontally by adjusting the mast supports on the front mast, so
that the extended radome top line ends at the fixed point.
4.2
Electrical measurements
4.2.1
CSB and SBO cables
Course Tx cables.
The CSB and SBO cable between the cabinet and MCU must be of equal electrical length.
Utilise a vector voltmeter or network analyser in a test set-up as in Figure 4-1.
Measure open cable return phase for each cable.
Refer to CSB cable as zero phase and measure the return phase for the SBO cable. The
cable pair must be matched within ±3.0° return phase, equal to ±1.5° true phase.
Clearance Tx cables.
Repeat the procedure 1.2.1 for CLR Tx CSB and SBO cables
Содержание NM 7000 Series
Страница 7: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 11: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 Figure 2 3 ...
Страница 13: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 19: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 21: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 23: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 25: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 27: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 31: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 45: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 55: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 65: ... ...
Страница 81: ... ...
Страница 111: ... ...
Страница 129: ... ...
Страница 132: ... ...
Страница 134: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 150: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...
Страница 158: ...1250 5 167580 17 1 1 6 67 0 167 7 21 200 66 21 1 1 22 1DYLD YLDWLRQ 6 ...