7
7/20 171215
Once the Casters or Legs are installed the unit can be returned to its upright position.
Be sure to work in pairs when returning the unit to the upright position.
NOTICE
Do not operate the unit for 1 hour after returning the unit to its upright position to allow
the oil to settle in the Compressor.
Shelf Installation
The appliance is supplied with one Shelf per door and four Shelf Supports per Shelf.
Install the Shelf Supports on the Shelf Pilasters (factory installed on inside walls) at the
height desired. All Shelf Supports must be at the same height for each Shelf. Install the
Shelf on the Shelf Supports.
Locating the Appliance
The unit needs to have Casters or Legs installed to operate properly.
IMPORTANT
•
Confirm that the floor in the installation location is strong enough to support the
unit.
•
Confirm that the ambient temperatures are within the tolerances allowed.
•
Do not locate next to heat generating appliances.
•
The unit is intended for indoor installation.
•
Confirm the unit is installed level.
•
Do not use an extension cord to connect the unit to power. Use of an extension
cord will void all warranties.
•
Do not tamper with the ground pin on the power cord and confirm that the power
receptacle has a properly wired ground connection.
•
The appliance must be isolated on a power circuit.
•
Confirm that the power supply matches the required power supply noted on the
cabinet serial plate.
•
Allow a minimum of 3 inched of space between the rear of the unit and the wall
for proper breathing.