Noritz ProTough BNR98-DVC-LP Скачать руководство пользователя страница 1

Potential dangers from accidents during installation and use are divided into the following three 
categories. Closely observe these warnings, they are critical to your safety.

Prohibited

Disconnect
Power

Ground

Be sure to do

WARNING:

 If the information in this manual is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or death.

NORITZ AMERICA 
CORPORATION

 Installation Manual

TANKLESS GAS WATER HEATER

NR981-DVC

 

 (Indoor Installation)

DANGER indicates an imminently hazardous situation which, 

if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, 

if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, 

if not avoided, may result in minor or moderate injury.

DANGER

WARNING

CAUTION

Requests to Installers

•  In order to use the water heater safely, read this installation manual carefully, and follow the in-

stallation instructions.

•  Failures and damage caused by erroneous work or work not as instructed in this manual are not 

covered by the warranty.

•  Check that the installation was done properly in accordance with this Installation Manual upon  

completion.

• 

After completing installation, please either place this Installation Manual in a plastic pouch and 

attach it to the side of the water heater (or the inside of the pipe cover or recess box if applicable), 

or hand it to the customer to retain for future reference.  Also, be sure to fill in all of the required 

items on the warranty and to hand the warranty to the customer along with the Owner's Guide.

CAUTION

SBA8871-2

Rev. 03/13

FOR USE IN RESIDENTIAL APPLICATIONS.
Installation must conform with local codes, or in the absence of local codes, 
the National Fuel Gas Code, ANSI Z223.1/NFPA 54- latest edition and/or 

CSA B149.1, Natural Gas and Propane Installation Code (NSCNGPIC).

Noritz America reserves the right to discontinue, or change at any 

time, the designs and/or specifications of its products without notice.

Low NOx 

Approved by 

SCAQMD

14 ng/J or 20 ppm

(Natural Gas Only)

CERTIFIED

R

*SBA8871*

Содержание ProTough BNR98-DVC-LP

Страница 1: ...ow the in stallation instructions Failures and damage caused by erroneous work or work not as instructed in this manual are not covered by the warranty Check that the installation was done properly in...

Страница 2: ...n Manual this document Part No Description 4 CVP 4STR 12 CVP 12STR 24 CVP 24STR 36 CVP 36STR Adjustable Part No Description CVT S Flange Adapter HorizontalTermination Flange Elbow Part No Description...

Страница 3: ...l connector from the other unit Note Connect the operation panel to only one of the units System Diagram Insulate the hot water piping to prevent heat loss Insulate and apply heating materials to the...

Страница 4: ...r The power supply required is 120VAC at 60Hz May result in fire or electric shock Use Extreme Caution if Using With a Solar Pre Heater Using this unit with a solar pre heater can lead to unpredictabl...

Страница 5: ...sult Avoid installation in places where special chemical agents e g hair spray or spray detergent are used Ignition failures and malfunction may occur as a result Carbon Monoxide Poisoning Hazard Do n...

Страница 6: ...al noises while it is running Before installing make sure that the exhaust flue termination will have the proper clearances according to the National Fuel Gas Code ANSI Z223 1 State of California The...

Страница 7: ...n the following clearances from both combustible and non combustible materials Check Illustration If possible leave 8 200mm or more on either side of the unit to facilitate inspection If possible leav...

Страница 8: ...ilding or the combustion air inlet to any other appliance K Clearance to a mechanical air supply inlet 6 ft 1 83 m L Clearance above paved sidewalk or paved driveway located on public property Clearan...

Страница 9: ...suffi cient reinforcement must be done to prevent the transfer of vibration Do not drop or apply unnecessary force to the device when installing Internal parts may be damaged and may become highly da...

Страница 10: ...or enclosure Blocked terminals can cause abnor mal combustion resulting in undesired performance from the water heater 8 Vent Pipe Installation This appliance requires the use of special concentric t...

Страница 11: ...ter heater before changing the dip switches Failure to perform this step will result in a 73 code displayed on the operation panel and a cease in operation If this occurs disconnect then reconnect pow...

Страница 12: ...this condensed water according to local codes and in order to prevent injury or property damage If this product will be installed in an area where snow is known to accumulate protect the vent termina...

Страница 13: ...on air intake of any appliance and 3 0 9m from any other building opening gas utility me ter service regulator etc Enclose exterior vent systems below the roof line to limit condensation and protect a...

Страница 14: ...I Z223 1 Natural Gas Meter See next page for the pipe capacity charts Noritz Tankless Gas Water Heater 199 900 Btuh Clothes Dryer 35 000 Btuh Barbecue 50 000 Btuh Gas Range Stove 65 000 Btuh 10 3m 10...

Страница 15: ...787 1496 55 112 213 440 675 1260 Maximum Capacity of Flex TracPipe in Cubic Feet per Hour of Natural Gas 0 60 Specific Gravity 0 5 WC Pressure Drop Length in Feet Pipe Size 3 4 1 1 1 4 1 1 2 2 206 383...

Страница 16: ...t be connected to any heating system or components previously used with a nonpotable water heating appliance When water is required in one part of the system at a higher temperature than in the rest o...

Страница 17: ...eans to ensure that the supply water pressure to the inlet of the heater does not fall below 29 PSI when the maximum amount of water is being demanded Also install a pressure meter on the inlet If thi...

Страница 18: ...ment Required Treatment Required Install Noritz Isolation Valves to allow for flushing Flushing is required if a water treatment device is not installed Suggested Suggested Install Noritz Isolation Va...

Страница 19: ...uastat to 10 F 5 C below the set output temperature 4 Noritz recommends the use of an Isolation Kit with the installation These kits include an integrated shut off and service valve with unions and a...

Страница 20: ...eater will not activate resulting in possible freezing damage Do not let the power cord contact the gas piping Tie the redundant power cord outside the water heater Putting the redundant length of cor...

Страница 21: ...anel To keep the water heater off let the unit sit for 30 sec to return to the original display This unit can be programmed so that it will default to one of three temperatures if the operation panel...

Страница 22: ...he water heater off by pressing the Power On Off Button on the operation panel 2 Disconnect then reconnect electrical power to the water heater 3 Press the Flow Meter Alarm Set Button and hold it in f...

Страница 23: ...m a wall circuit to the pump 5 Replace the front cover Pump Wiring This feature is not available when using the Quick Connect Multi System feature Relay connection with larger pumps 85 W 1 Locate and...

Страница 24: ...Coupling Cord Clamp Ground wire Connector Connector Connecting Quick Connect Cord 2 Caution For Quick Connect Multi System Installation use part QC 2 only sold separately Quick Connect Cord 2 Quick Co...

Страница 25: ...roper blue color and consistency If the flame does not appear normal the burner may need to be cleaned If the burner needs to be cleaned it must be performed by a qualified service technician Do not o...

Страница 26: ...ower to the unit 8 The unit will now operate whenever hot water is called for If the unit will not operate follow the shutdown instructions and call a service technician Shutdown Instructions 1 Stop a...

Страница 27: ...OF EACH FITTINGS FROM BOTTOM OF CASE GAS INLET COLD WATER INLET HOT WATER OUTLET NR 981 DVC 2 0 5 13mm 1 4 36mm 2 8 70mm 3 9 100mm 5 5 140mm 1 0 26mm 24 6 626mm 22 3 567mm 23 6 600mm 4 4 113mm 4 0 10...

Страница 28: ...r In order to use this product safely read this installation manual carefully and follow the installation instructions Potential dangers from accidents during installation and use are described below...

Страница 29: ...List The value in indicates the quantity Remote Controller Mounting bracket Raised countersunk head wood screw Wall anchor Raised countersunk head screw For junction box installation Machine screw Whe...

Страница 30: ...f the remote controller and the frame pull the entire decorative frame forward while pressing the sections indicated where the fingers are in the figure below If it does not come off insert a flat hea...

Страница 31: ...wires ant the Y shaped terminals two cord of remote controller cord 4 Wire the remote controller cord through the wiring throughway and connect them to the wiring inside the heater 5 Replace the fron...

Страница 32: ...Press the ENTER Button the Misc settings screen appears on the display 4 Select Max set Temp using the Buttons 5 Press the ENTER Button 120 F 50 C appears on the display 6 Set the upper limit of the...

Страница 33: ...controller 2 Disconnect then reconnect electrical power to the water heater 3 Press the MENU Button inside the cover select Initial settings using the Buttons 4 Press the ENTER button the Initial set...

Отзывы: