19
How to use Control Panel- User mode
Chapter 3. – Unit Operation
1. Select the ‘[I:EH] mode’ by turning the
‘Dial Button’ in ‘User Mode’.
2. ERROR CODE that have occurred can
be identified and ‘E0.11’ character is flash-
ing when the ‘Dial Button’ is pressed in
‘[I:EH] mode’.
3. ERROR CODE that have occurred from E0 to E9 can
be identified by turning the ‘Dial Button’ clockwise.
4. Pressed the ‘Dial Button’ to return to ‘User Mode’
Error history
mode
[For example]
1’st error occurs : 11
2’nd error occurs: 16
4. How to check the ‘Error History’. [I:EH]
- Refer to page 18 ‘User mode’ setting method and set to ‘User mode’.
- Function can be checked by turning the dial button.
- Refer to page 18 ‘User Mode’ setting method and set to ‘User mode’.
- Function can be checked by turning the dial button.
1. Select the ‘[C:TL] mode’ by turning the
‘Dial Button’ in ‘User Mode’.
2. ‘Lock Mode’ is started and ‘oFF’ character
is flashing when the ‘Dial Button’ pressed in
‘[C:TL] mode’.
3. Select the ‘on’ character by turning the
‘Dial Button’ clockwise.
‘Temperature Lock’ Icon
Temperature
Lock mode
3. Locking the Control Panel. [C:TL]
By locking the control panel, the settings cannot be accidentally changed if a button is pressed by mistake.
4. Press the ‘Dial Button’ to store, lock icon is
displayed. And return to ‘User Mode’