10
Illustration
7.
Installation
Check
4. Drill holes for the remaining four screws.
5. Hang the unit again by the first screw, and then
insert and tighten the remaining four screws.
6. Take waterproofing measures so that water does
not enter the building from screws mounting the
device.
• Make sure the unit is installed securely so that it will
not fall or move due to vibrations or earthquakes.
Securing to the wall
Mounting Bracket
(upper)
Tapping Screw
Location of Screw Hole
1. Drill a single screw hole, making sure to hit a stud.
2. Insert and tighten the screw and hang the unit by
the upper wall mounting bracket.
3. Determine the positions for the remaining four screws
(two for the top bracket and two for the bottom), and
remove the unit.
• The weight of the device will be applied to the wall. If the strength of the wall is not suffi-
cient, reinforcement must be done to prevent the transfer of vibration.
• Do not drop or apply unnecessary force to the device when installing. Internal parts may
be damaged and may become highly dangerous.
• Install the unit on a vertical wall and ensure that it is level.
Locating Screw Holes
Locating Screw Holes
Mounting
Structure
• When installing with bare hands, take caution to
not inflict injury.
• Be careful not to hit electrical wiring, gas, or water
piping while drilling holes.
Item
CAUTION
Be sure to do
• If this water heater is being installed at an elevation of
610m (2,000') or higher, disconnect the connector la-
beled "High Elevation Disconnect" as illustrated on the
right. This connector is located inside the unit.
Installations at Elevations
Above 610m (2,000').
HIGH ELEV
ATION
DISCONNECT
• Disconnect power to the water heater before discon-
necting this connector. Failure to perform this step will
result in a "73" code displayed on the remote controller
and a cease in operation. If this occurs, disconnect,
then reconnect power to the water heater to reset the
system.