 Water Piping

This appliance suitable for potable water and space heating applications. Do not use this appliance if any part has
been underwater.  Immediately call a qualified service technician to inspect the appliance and replace any part of the
control system and gas control which has been under water.

If the water heater is installed in a closed water supply system, such as one having a backflow preventer in the cold
water supply line, means shall be provided to control thermal expansion. Contact the water supplier or a local plumb-
ing inspector on how to control this situation.

A pressure relief valve must be installed near the hot water outlet that is rated in accordance with and complying with
either The Standard for Relief Valves and Automatic Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22, or
The ANSI/ASME Boiler and Pressure Vessel Code, Section IV ( Heating Boilers ). This pressure relief valve must
be capable of an hourly Btu rated temperature steam discharge of 199,900 Btuh. Multiple valves may be used. The
pressure relief capacity must not exceed 150 psig. No valve shall be placed between the relief valve and the water
heater. The relief valve must be installed such that the discharge will be conducted to a suitable place for disposal
when relief occurs. No reducing coupling or other restriction may be installed in the discharge line. The discharge line
must be installed to allow complete drainage of both the valve and the line. If this unit is installed with a separate
storage vessel, the separate vessel must have its own temperature and pressure relief valve. This valve must also
comply with The Standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI
Z21.22. (in the U.S. only). A temperature relief valve is not required, but if one is used, do not install the valve with the
probe directly in the flow of water. This may cause unwarranted discharge of the valve.

Piping and components connected to the water heater shall be suitable for use with potable water.
Toxic chemicals, such as those used for boiler treatment, shall not be introduced into the potable water.
A water heater used to supply potable water may not be connected to any heating system or components previously
used with a nonpotable water heating appliance.
When water is required in one part of the system at a higher temperature than in the rest of the system, means such
as a mixing valve shall be installed to temper the water to reduce the scald hazard.

Installation and service must be performed by a qualified plumber.  In the
Commonwealth of Massachusetts, this product must be installed by a licensed
plumber or gas fitter in accordance with the Massachusetts Plumbing and Fuel
Gas Code 248 CMR Sections 2.00 and 5.00. Observe all applicable codes.

• Flush water through the pipe to clean out metal powder, sand and dirt before connecting it.
• Perform the following insulation measures for prevention of freezing.

• Take appropriate heat insulation measures (e.g., wrapping with heat

insulation materials, using electric heaters) according to the climate of
the region to prevent the pipe from freezing.

• Make sure that there are no water leaks from the cold and hot water

supply pipes, then insulate the pipes completely.

• Be sure to also completely insulate the water supply valve and the

cold and hot water connections on the water heater (refer to the figure
on the right).

• Do not cover the water drain plug with insulation so that water in the

pipe can be drained. (Refer to the figure in the right.)

• Use a union coupling or flexible pipe for connecting the pipes to reduce the force applied to the piping.
• Do not use piping with a diameter smaller than the coupling.
• When feed water pressure is too high, insert a depressurizing valve, or take water hammer prevention measure.
• Avoid using joints as much as possible to keep the piping simple.
• Avoid piping in which an air holdup can occur.
• If installing the unit on a roof:
• About lower-level hot water supply

If the unit is installed on a roof to supply water to the levels below, make sure that the water pressure supplied to
the unit does not drop below 29 psi. It may be necessary to install a pump system to ensure that the water pressure
is maintained at this level.
Check the pressure before putting the unit into operation.
Failure to supply the proper pressure to the unit may result in noisy operation, shorter lifetime of the unit, and may
cause the unit to shut down frequently.

Completely insulate  
the water inlet and  
outlet fittings. 

Insulate the water  
supply valve completely.

Do not cover the water  
drain plug with insulation   
so that water in the pipe  
can be drained.

Содержание N-0751M-DV

Страница 1: ...ucted in this manual are not covered by the warranty Check that the installation was done properly in accordance with this Installation Manual upon completion After completing installation please eith...

Страница 2: ...p 20 Remote Controller Cord 10ft 1 2 Optional Accessories The accessories listed below are not included with the units but may be necessary for installation Q ty Shape Part Part Shape Q ty Flue Termi...

Страница 3: ...etween the two units When connecting two units use only a single remote controller Note Connect the remote controller to only one of the units System Diagram Insulate the hot water piping to prevent h...

Страница 4: ...to ensure output temperatures do not get to scalding levels Do not use a solar pre heater with the quick connect multi system Precautions on Vent Pipe Replacement The vent system will almost certainl...

Страница 5: ...as a result Avoid installation in places where special chemical agents e g hair spray or spray detergent are used Ignition failures and malfunction may occur as a result Carbon Monoxide Poisoning Haza...

Страница 6: ...ing to the National Fuel Gas Code ANSI Z223 1 State of California The water heater must be braced anchored or strapped to avoid moving during an earthquake Contact local utilities for code requirement...

Страница 7: ...s restriction will not be applied to an area where an effective shield makes a clearance of 24 or more in front of the exhaust outlet Check Illustration If possible leave 8 or more on either side of t...

Страница 8: ...ter regulator assembly 3 within a height 15 above meter regulator assembly I Service regulator vent outlet 3 J Nonmechanical air supply inlet or combustion air inlet to any other appliance 12 36 K Mec...

Страница 9: ...Locating Screw Holes Mounting Structure When installing with bare hands take caution to not inflict injury Be careful not to hit electrical wiring gas or water piping while drilling holes Item CAUTIO...

Страница 10: ...oo far Snow drift Tree Avoid installing the terminal where obstacles will block it Clearance from vent terminal If multiple units are installed terminals must be separated by 12 or more in a plain vie...

Страница 11: ...in bad combustion If possible don t install the vent pipe through any enclosed areas If necessary consult the pipe manufacturer s instructions for clearances Install the vent terminal so that all exh...

Страница 12: ...straight upwards Always have a horizontal section of venting Install a condensation drain in the horizontal section of the venting Appliance Adapter Firestop Firestop Support Roof Flashing RainCap Exh...

Страница 13: ...he gas line consult local codes or the National Fuel Gas Code ANSI Z223 1 Natural Gas Meter See next page for the pipe capacity charts Noritz N 0751M DV 199 900 Btuh Clothes Dryer 35 000 Btuh Barbecue...

Страница 14: ...c Feet per Hour of Natural Gas 0 60 Specific Gravity 0 5 WC Pressure Drop Length in Feet Pipe Size 3 4 1 1 1 4 1 1 2 2 10 20 30 40 50 60 70 80 90 100 150 200 206 383 614 1261 2934 147 269 418 888 2078...

Страница 15: ...em or components previously used with a nonpotable water heating appliance When water is required in one part of the system at a higher temperature than in the rest of the system means such as a mixin...

Страница 16: ...wet the floor If neces sary provide drain piping or use a drain hose to remove the water Hot water piping Do not use lead PVC iron or any piping which has been treated with chromates boiler seal or ot...

Страница 17: ...Heater Optional Sediment Filter Water Treatment Device Shutoff Valve Type of Water Hardness Level Treatment Device Flush Frequency Type of Water Hardness Level Treatment Device Flush Frequency Soft 0...

Страница 18: ...pump 4 Set the flow switch to deactivate the Air Handler when the domestic hot water flow reaches 3 GPM Adjust as necessary to prevent cycling 5 If the system requires water for space heating at a hig...

Страница 19: ...e water heater Putting the redundant length of cord inside the water heater may cause electrical interference and faulty operation Disconnect Power Electrical Shock Hazard Do not turn power on until e...

Страница 20: ...s shown on the right 5 Replace the front cover of the water heater 4 screws 6 Reconnect electrical power to the water heater but do not turn it on 7 Press and hold the FLOW METER ALARM SET button unti...

Страница 21: ...and cause problems Be sure to hand tighten when screwing to the terminal block Power tools may cause damage to the terminal block 1 Check to make sure that the remote controller cord has plenty of sl...

Страница 22: ...m a wall circuit to the pump 5 Replace the front cover Pump Wiring This feature is not available when using the Quick Con nect Multi System feature Relay connection with larger pumps 85 W 1 Locate and...

Страница 23: ...lack 3 White 4 Green 5 Blue 6 Blue 1 White 2 Green 3 Red 4 Black 5 Blue 6 Blue Connecting the Quick Connect Cord to the two units 1 Turn off the power 2 Remove the front cover of the heater 4 screws 3...

Страница 24: ...r a proper blue color and consistency If the flame does not appear normal the burner may need to be cleaned If the burner needs to be cleaned it must be performed by a qualified service technician Do...

Страница 25: ...ower to the unit 8 The unit will now operate whenever hot water is called for If the unit will not operate follow the shutdown instructions and call a service technician Shutdown Instructions 1 Stop a...

Страница 26: ...5 3 9 2 8 1 4 17 7 120VAC WIRING THROUGHWAY WIRING THROUGHWAY COLD WATER INLET WATER DRAIN VALVE WATER FILTER HOT WATER OUTLET WATER DRAIN VALVE GAS INLET 1 1 3 0 4 23 1 9 4 0 4 3 7 1 6 FLUE COLLAR A...

Страница 27: ...otes on the Installation Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid locat...

Страница 28: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Отзывы: