background image

11

• Do not store hazardous or flammable sub-

stances near the vent terminal,

• Slope the intake and exhaust pipes downwards

1/4" for every 12" towards the termination.

• Use only UL listed Category III venting products.
• Connect the vent pipe firmly so that it will prevent

exhaust gases from leaking.

• Steam or condensed water may drip out of the

vent terminal.Dispose of this condensed water
according to local codes and in order to prevent
injury or property damage.

• If this product will be installed in an area where

snow is known to accumulate,protect the vent
termination from blockage by snow drifts or dam-
age from snow falling off of roofs.

• Support the vent pipe with hangers at intervals

as required by the vent pipe manufacturer ’s in-
stallation instructions.

• Install the vent terminal so that it is easily

accesible for maintenance both from the indoors
and the outdoors.

• If the vent terminal will be installed higher than

the water heater,make the vertical section di-
rectly above the water heater as short as
possible,and slope down to the terminal. Do not
have another vertical section after the horizontal
section begins.

• Make the vertical pipe as short as possible.

Venting Precautions

• Use 4" diameter Category III vent pipe.
• Maximum vent length

• Exceeding the maximum vent length is danger-

ous and may result in bad combustion.

• If possible,don ’t install the vent pipe through any

enclosed areas.If necessary,consult the pipe
manufacturer ’s instructions for clearances.

• Install the vent terminal so that all exhaust is di-

rected to and all intake air is taken from outdoors.

• In the Commonwealth of Massachusetts a car-

bon monoxide detector is required for all side
wall horizontally vented gas fuel equipment.
Please refer to Technical Bulletin TB 010606 for
full installation instructions.

Number of 90

degree elbows

4

3

2

1

Maximum

Vent Length

39'

45'

51'

57'

• Do not common vent or connect more than

one appliance to this venting system.

Appliance Adapters

• Use the following adapters to connect the

unit to the venting system.

Manufacturer and

Enclosed

Unenclosed

Product

Hor. Vert.

Hor.

Vert.

 Noritz N-Vent

4"

1"

1"

 Protech FasNSeal

4"

3"

3"

 Protech FasNSeal W2

6"

4"

3"

3"

 HeatFab SafTVent

6"

6"

2"

2"

 Z-Flex Z-Vent

8"

4"

1"

1"

 Flex-L-StaR-34

8"

4"

1"

1"

These clearances are subject to change.
Refer to the UL listing for the proper clearances.

8" (sides)
12"(top)
4"(bottom)

Manufacturer and

Product

  Protech FasNSeal

FSAA4

  HeatFab SafTVent

9401RYPK

  Z-Flex Z-Vent

2SVWA04

  Flex-L StaR-34

SRASPSA4

Part No.

• Follow the vent pipe manufacturer's installation

instructions.

• Maintain the same vent pipe diameter all the

way to the end.

• Maintain the following clearances for the

exhaust pipe to combustibles:

• Terminate at least 12"above grade or snow line
• Terminate at least 7'above a public walkway
• Use a condensation drain if necessary

10" (sides)
15"(top)
6"(bottom)

Содержание N-0751M-DV

Страница 1: ...ucted in this manual are not covered by the warranty Check that the installation was done properly in accordance with this Installation Manual upon completion After completing installation please eith...

Страница 2: ...p 20 Remote Controller Cord 10ft 1 2 Optional Accessories The accessories listed below are not included with the units but may be necessary for installation Q ty Shape Part Part Shape Q ty Flue Termi...

Страница 3: ...etween the two units When connecting two units use only a single remote controller Note Connect the remote controller to only one of the units System Diagram Insulate the hot water piping to prevent h...

Страница 4: ...to ensure output temperatures do not get to scalding levels Do not use a solar pre heater with the quick connect multi system Precautions on Vent Pipe Replacement The vent system will almost certainl...

Страница 5: ...as a result Avoid installation in places where special chemical agents e g hair spray or spray detergent are used Ignition failures and malfunction may occur as a result Carbon Monoxide Poisoning Haza...

Страница 6: ...ing to the National Fuel Gas Code ANSI Z223 1 State of California The water heater must be braced anchored or strapped to avoid moving during an earthquake Contact local utilities for code requirement...

Страница 7: ...s restriction will not be applied to an area where an effective shield makes a clearance of 24 or more in front of the exhaust outlet Check Illustration If possible leave 8 or more on either side of t...

Страница 8: ...ter regulator assembly 3 within a height 15 above meter regulator assembly I Service regulator vent outlet 3 J Nonmechanical air supply inlet or combustion air inlet to any other appliance 12 36 K Mec...

Страница 9: ...Locating Screw Holes Mounting Structure When installing with bare hands take caution to not inflict injury Be careful not to hit electrical wiring gas or water piping while drilling holes Item CAUTIO...

Страница 10: ...oo far Snow drift Tree Avoid installing the terminal where obstacles will block it Clearance from vent terminal If multiple units are installed terminals must be separated by 12 or more in a plain vie...

Страница 11: ...in bad combustion If possible don t install the vent pipe through any enclosed areas If necessary consult the pipe manufacturer s instructions for clearances Install the vent terminal so that all exh...

Страница 12: ...straight upwards Always have a horizontal section of venting Install a condensation drain in the horizontal section of the venting Appliance Adapter Firestop Firestop Support Roof Flashing RainCap Exh...

Страница 13: ...he gas line consult local codes or the National Fuel Gas Code ANSI Z223 1 Natural Gas Meter See next page for the pipe capacity charts Noritz N 0751M DV 199 900 Btuh Clothes Dryer 35 000 Btuh Barbecue...

Страница 14: ...c Feet per Hour of Natural Gas 0 60 Specific Gravity 0 5 WC Pressure Drop Length in Feet Pipe Size 3 4 1 1 1 4 1 1 2 2 10 20 30 40 50 60 70 80 90 100 150 200 206 383 614 1261 2934 147 269 418 888 2078...

Страница 15: ...em or components previously used with a nonpotable water heating appliance When water is required in one part of the system at a higher temperature than in the rest of the system means such as a mixin...

Страница 16: ...wet the floor If neces sary provide drain piping or use a drain hose to remove the water Hot water piping Do not use lead PVC iron or any piping which has been treated with chromates boiler seal or ot...

Страница 17: ...Heater Optional Sediment Filter Water Treatment Device Shutoff Valve Type of Water Hardness Level Treatment Device Flush Frequency Type of Water Hardness Level Treatment Device Flush Frequency Soft 0...

Страница 18: ...pump 4 Set the flow switch to deactivate the Air Handler when the domestic hot water flow reaches 3 GPM Adjust as necessary to prevent cycling 5 If the system requires water for space heating at a hig...

Страница 19: ...e water heater Putting the redundant length of cord inside the water heater may cause electrical interference and faulty operation Disconnect Power Electrical Shock Hazard Do not turn power on until e...

Страница 20: ...s shown on the right 5 Replace the front cover of the water heater 4 screws 6 Reconnect electrical power to the water heater but do not turn it on 7 Press and hold the FLOW METER ALARM SET button unti...

Страница 21: ...and cause problems Be sure to hand tighten when screwing to the terminal block Power tools may cause damage to the terminal block 1 Check to make sure that the remote controller cord has plenty of sl...

Страница 22: ...m a wall circuit to the pump 5 Replace the front cover Pump Wiring This feature is not available when using the Quick Con nect Multi System feature Relay connection with larger pumps 85 W 1 Locate and...

Страница 23: ...lack 3 White 4 Green 5 Blue 6 Blue 1 White 2 Green 3 Red 4 Black 5 Blue 6 Blue Connecting the Quick Connect Cord to the two units 1 Turn off the power 2 Remove the front cover of the heater 4 screws 3...

Страница 24: ...r a proper blue color and consistency If the flame does not appear normal the burner may need to be cleaned If the burner needs to be cleaned it must be performed by a qualified service technician Do...

Страница 25: ...ower to the unit 8 The unit will now operate whenever hot water is called for If the unit will not operate follow the shutdown instructions and call a service technician Shutdown Instructions 1 Stop a...

Страница 26: ...5 3 9 2 8 1 4 17 7 120VAC WIRING THROUGHWAY WIRING THROUGHWAY COLD WATER INLET WATER DRAIN VALVE WATER FILTER HOT WATER OUTLET WATER DRAIN VALVE GAS INLET 1 1 3 0 4 23 1 9 4 0 4 3 7 1 6 FLUE COLLAR A...

Страница 27: ...otes on the Installation Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid locat...

Страница 28: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...