![Noritz GQ-C3259WZ-FF US Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/noritz/gq-c3259wz-ff-us/gq-c3259wz-ff-us_installation-manual_1705159005.webp)
5
: Max.
:
: AC 120Volts 60Hz, less than
amperes
Btu/h
Btu/h - Min.
Gal/h
(
: Min.
psi
psi
- Max.
:
"W.C.
l/h)
: Min.
"W.C.
"W.C.- Max.
-For Indoor, Outdoor or Manufactured Home(Mobile Home) Installation.
(Pour installation dans une maison préfabriquée(Mobile)).
Model
(Modèle)
:
Type of Gas
(Type de gaz)
Input Rating
(Debit calorifique)
Recovery Rating
(Calibre de recouvrement)
Inlet Gas Pressure
(Pression de gaz entrée)
Manifold Pressure
(Pression d’admission)
Water Supply Pressure
(Pression d’eau)
Electrical Rating
(Régime nominal électrique)
-For gas conversion information, contact Noritz America.
(Pour I’ information de conversion de gaz, contact Noritz America.)
-Direct Vent Automatic Instantaneous Water Heater (“Category IV”).
(Chauffe-eau instantané automatique à évent direct
(“Catégorie IV”).)
-Installations above 2000 ft(610m) require an adjustment. See Installation Instructions for
details.
(Installations au-dessus de 2000 ft(610m) exigent un ajustement. Voir les
instructions d’installation pour des détails.)
QR
CODE
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fountain Valley, CA 92708
Tel
(Tél )
: (866)766-7489
Made in Japan
(Fabriqué au JAPON)
: Natural Gas
(Gaz Naturel)
Low NOx approved by SCAQMD(<14ng/J or 20ppm)
ANSI Z21.10.3
・
CSA 4.3-2015
18,000
199,900
237
897
150
15
0
3.5
10.5
4
NCC199CDV(GQ-C3259WZ-FF US)
4.
Before Installation
Checkup
• Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary.
DANGER
Do Not Use Equipment for Purposes Other Than Those Specified
• Do not use for other than increasing the temperature of the water supply, as unexpected accidents
may occur as a result.
Check Water Supply Quality
• If the water supply is in excess of 12 grains per gallon (200 mg/L) of hardness, acidic or otherwise
impure, treat the water with approved methods in order to ensure full warranty coverage.
WARNING
CAUTION
Check the Gas
• Check that the rating plate indicates the
correct type of gas.
• Check that the gas supply line is sized for
199,900 Btuh.
Check the Power
• The power supply required is 120VAC, at 60Hz.
Using the incorrect voltage may result in fire or electric shock.
Use Extreme Caution if Using With a Solar Pre-Heater
• Using this unit with a solar pre-heater can lead to unpredictable output temperatures and
possibly scalding. If absolutely necessary, use mixing valves to ensure output temperatures do
not get to scalding levels. Do not use a solar pre-heater with the quick-connect multi-system.
Precautions for Mobile Home Installation
• Verify that the gas supply type matches the gas type listed on the rating plate. If a gas conversion
must be done, follow the instructions listed in the gas conversion kit manual.
• If this product will be installed indoors, usage of the SV conversion kit (SV-CK-2) is prohibited.
Make sure to follow all clearance and venting requirements outlined in this manual.
e.g. NCC199CDV(GQ-C3259WZ-FF US)
Precautions on Vent Pipe Replacement
• The vent system will almost certainly need to be replaced when this appliance is being installed.
Only use vent materials that are specified in this Installation Manual for use on this appliance.
Refer to the "Venting the Water Heater" section for details. If PVC, CPVC, or Category IV listed pipe is
already installed, check for punctures, cracks, or blockages and consult with the vent pipe manufacturer
before reusing.
Improper venting may result in fires, property damage or exposure to Carbon Monoxide.
Snow Precaution
• If this product will be installed in an area where snow is known to accumulate, protect the vent
termination from blockage by snow drifts or damage from snow falling off of roofs.