1-1 SHIPPING DAMAGE AND SHORTAGES:
Before and after the crated machine is unloaded from the truck, the crate should be inspected for any
signs of damage. Is suspected damage is found, it must be noted on the bill of lading and signed by the
driver and the person receiving the shipment. After the machine has been uncrated, inspect it and all
other contents of the crate for damage. In the event that damage has occurred in transit, notify the freight
carrier and Norfield immediately. Inspect the complete shipment against the packing slip to make sure
all items listed are accounted for. If any shortages are noticed, the freight carrier and Norfield should be
notified immediately.
1-2 POSITIONING:
After the machine has been uncrated, remove it from the crate base and put it in its permanent location.
Since machine vibration is not sufficient enough to cause the machine to “creep”, there is no need to
secure it to the floor. If desired, the machine can be leveled by installing leveling bolts (1/2-13 x 1-1/2” hex
bolts work fine) in the holes provided in the leg bases.
1-3 ELECTRICAL SUPPLY AND CONNECTIONS:
Before connecting electrical power to the machine, make sure that the power run to the machine matches
the information on the electrical requirement plate (located on the door of the electrical enclosure).
The 250MX requires an electrical input of 115VAC @ 20 amps. It is equipped with a standard 3 prong
115 volt grounded plug for easy connection. If an extension cord is used, 14 gauge is recommended as a
minimum. If you prefer, the machine can be wired directly. To do so, remove the cord from the electrical
control box and connect the supply to the same terminals. Either way, take care to keep the power cord
clear of the operator and material movement. It is recommended that an electrical disconnect be pro
-
vided near the machine for disconnecting all power from the machine when maintenance or adjustments
are performed.
1-4 AIR SUPPLY AND CONNECTIONS:
Clean dry air is vital for the continued performance and low maintenance of air operated tools and equip
-
ment. Dirt, grit, moisture and pipe scale can cause severe abrasive wear in valves and cylinders. Nor
-
field highly recommends that a filter-regulator unit be installed in the feeder line to the machine and the
regulator set to 90 PSI. We also recommend the use of an air drying system to give maximum life to all
your air tools.
Connect air to the 250MX at port #3 on the foot pedal valve.
1-5 MACHINE HEIGHT:
The height of the machine can be set at one of three heights: 26”, 30” or 34”. Remove the bolts that attach
the main frame to the lower legs and set the height that is most comfortable for the operator.
Содержание 250MX
Страница 1: ...OWNERS MANUAL Release 3 250MX STRIKE JAMB ROUTER Effective S N SR 3210MX Document Number 17 346...
Страница 2: ...2 First Release April 2008 Second Release May 2008 Third Release November 2015...
Страница 4: ...4 This Page is Intentionally Blank...
Страница 27: ...27 ASSEMBLY SCHEMATICS This Page is Intentionally Blank...
Страница 30: ...30 NOTES NOTES...
Страница 31: ...31 NOTES NOTES...