SINGLE PACKAGE CONVERTIBLE AIR CONDITIONER

USER’S MANUAL / INSTALLATION INSTRUCTIONS

Please read this information thoroughly and become familiar with the capabilities and 
use of your appliance before attempting to operate or maintain this unit. Keep this 
literature where you have easy access to it in the future. If a problem occurs, check the 
instructions and follow recommendations given. If these suggestions don’t eliminate 
your problem, call your servicing contractor.

These instructions are primarily intended to assist qualifi ed individuals experienced in 
the proper installation of this appliance. Some local codes require licensed installation/
service personnel for this type of equipment. Please read all instructions carefully before 
starting the installation.

DO NOT DESTROY. PLEASE READ CAREFULLY AND 

KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

IMPORTANT

Premium Model Shown

P6SD SERIES

13 SEER

Содержание P6SD Series /installation

Страница 1: ...tions and follow recommendations given If these suggestions don t eliminate your problem call your servicing contractor These instructions are primarily intended to assist qualified individuals experi...

Страница 2: ...2...

Страница 3: ...rves 16 Figure 12 Wiring Diagram PSC Motor Three Phase 208 230V 17 Figure 13 Wiring Diagram Fixed Torque Motor Three Phase 208 230V 18 Figure 14 Wiring Diagram PSC Motor Single Phase 208 230V 19 Figur...

Страница 4: ...arnings and any other special notes highlighted in the manual Safety markings are used frequently throughout this manual to designateadegreeorlevelof seriousnessandshouldnot be ignored WARNING indicat...

Страница 5: ...refrigerant underhighpressure Installationorservicingshouldonly beperformedbyqualifiedtrainedpersonnelthoroughly familiar with this type equipment All electrical wiring must be completed in accordance...

Страница 6: ...lated to minimize duct losses and prevent condensation Use insulation with an outer vapor barrier Refer to local codes for insulation material requirements Acoustical Duct Work Certain installations m...

Страница 7: ...ter Size Requirements AIR CONDITIONER INSTALLATION Packaging Removal Remove the shipping carton and User s Manual from the equipment Take care not to damage the tubing connections when removing the ca...

Страница 8: ...the bottom of the filter is within the channels of the rack 4 Slide the 2nd filter between both guide channels of filter rack 5 Verify the bottom of the filter is within the channels of the rack 6 Rep...

Страница 9: ...08V operation remove the lead from the transformer terminal marked 240V and connect it to the terminal marked 208V Internally mounted circuit breakers are available as field installed options These ci...

Страница 10: ...age imbalance by using the results from steps 2 3 in the following equation max voltage deviation from average voltage 100 x average voltage Voltage Imbalance 6 454 100 x 1 32 Example 1 M e a s u r e...

Страница 11: ...blue wire Motor leads are code Q in Figure 8 High speed Connect the black wire to terminal 3 on the relay Tie off the orange red and blue wires They are not connected for high speed Fixed Torque ECM...

Страница 12: ...and compressor cycle off with the thermostat NOTE The blower should also stop unless fan mode is set to ON Refrigerant Charging WARNING Single Packaged Air Conditioners are shipped fully charged with...

Страница 13: ...s necessary using a mild detergent and water Rinse thoroughly with water Inspect the electrical connections for tightness at the beginningofeachheatingandcoolingseason Service as necessary Inspect and...

Страница 14: ...IZONTAL RETURN DUCT OPENING 4 0 CONDENSING COIL 5 0 8 4 00 Table 4 Center of Gravity Unit Shipping Weights Model Number P6SD Unit Weight Center of Gravity Height C in inches A B with base rails withou...

Страница 15: ...pplied for 1 Stage Cool 1 Stage Heat R Y1 Y2 C G 1 2 3 4 5 6 7 8 9 Gray Yellow Blue ECONOMIZER PLUG INDOOR THERMOSTAT SUB BASE Red Black Green FROM TRANSFORMER FROM CONTACTOR FROM BLOWER RELAY Optiona...

Страница 16: ...80 1260 1230 Tap T3 1740 1690 1650 1600 1360 1500 1460 1390 Tap T4 1960 1910 1840 1820 1540 1740 1700 1600 Tap T5 2090 2050 2010 1975 1780 1900 1850 1790 NOTES Airflow performance is with a dry coil D...

Страница 17: ...des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V la terre 5 For supply wire ampacities and overcurrent protection see unit rating plate 711011S 1 2 3 4 5 6 7 8 9 R C S 1...

Страница 18: ...0 V la terre 7110100 1109 FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE 711010M 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 R C S 1 5 2 6 3 4 TO 208 230 VAC POWER SUPPLY 9 8 1 7 6 5 4 3 2 9 8 1 7 6 5 4 3 2 9 8...

Страница 19: ...NG LEGEND LOW VOLTAGE HIGH VOLTAGE L C M H 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 BLOWER PLUG BLOWER MOTOR 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6...

Страница 20: ...de plus de 150V a la terre 711034o 1 2 3 4 5 6 7 8 9 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 3 AMP FUSE CCH COMPRESSOR OUTDOOR FAN MOTOR HEATER PLUG BLOWER RELAY DUAL C...

Страница 21: ...BLACK YELLOW BLACK BLUE BLACK WHITE RED YELLOW YELLOW BK BK BK WHITE WHITE NOTES FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE 460 Volt z H 0 6 e s a h P e e r h T r e n o i t i d n o C r i A d e g a k...

Страница 22: ...RED RED RED RED ORANGE ORANGE ORANGE ORANGE BLACK BLACK BLACK BLACK BLACK BLACK BLUE RED BLACK BLUE BROWN YELLOW YELLOW BLACK BK BK HEATER PLUG z H 0 6 e s a h P e e r h T t l o V 0 6 4 NOTES 1 Discon...

Страница 23: ...5 130 135 Add refrigerant when below curve Remove refrigerant when above curve Figure 18 Charging Chart for 3 Ton Units Liquid Pressure psig Liquid Temperature F 200 220 240 260 280 300 320 340 360 38...

Страница 24: ...TALLATION INSTRUCTIONS WITH THE HOMEOWNER COOLING CHARGING CHARTS 13 SEER A C CONTINUED 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600 620 75 80 85 90 95 100 105 110 115 1...