8
Table 3. Unit Specifications
1. Heating output rated at listed voltage. For outputs at voltages other than
240V, multiply Btuh rating by the following factors: x 0.92 (230V), x 0.84
(220V), x 0.75 (208V)
2. Height is 56" with return air grille installed, 58" with coil cabinet and 72" with
coil cabinet and upflow stand.
3. The factory installed blower for the EH models can be replaced with a multi-
speed blower allowing the units to accept up to 4 or 5 tons of air conditioning
or heat pump.
4. The factory installed blower for the EB models can be replaced with a multi-
speed blower allowing the units to accept up to 5 tons of air conditioning or
heat pump.
Electric Furnace Models
E2EH
010H
012H
015H
017H
020H
023H
Rated Heating Output, Btuh
(see note1) 35,000 41,000 53,000 57,000 70,000 75,000
Watts (Total kw, Heating Elements
and Blower)
10.4
12.0
15.4
16.6
20.4
22.0
Supply Voltage
Heating Elements, No.(Total kw) 2 (10.0) 2 (11.6) 3 (15.0) 3 (16.2) 4 (20.0) 4 (21.6)
Blower: Wheel Size
10.5" Dia., 8" Wide
Motor Speeds, H.P. Rating, Amps
2 Speed, 1/5 Hp, 2.0 Amps
Test ESP, in. w.c. Max
Optional Cooling Available with factory
installed blower
2.0 - 3.0 ton (see note 3)
Optional Heat Pump Available with
factory installed blower
2.0 - 3.0 ton (see note 3)
n/a (see note 3)
Air Filter (Standard)
Furnace Dimensions
Width - 20" (508 mm) Height
E2EB
010H
012H
015H
017H
020H
023H
023H 5 Ton
35,000 41,000 53,000 57,000 70,000 75,000
75,000
10.4
12.0
15.4
16.6
20.4
22.0
22.0
2 (10.0) 2 (11.6) 3 (15.0) 3 (16.2) 4 (20.0) 4 (21.6)
4 (21.6)
10.5" Dia., 8" Wide
11" Dia., 8" W
4 Speed, 1/3 Hp, 2.9 Amps
4 Spd, 3/4 Hp, 3.8 Amps
2.0 - 4.0 ton (see note 4)
2.0 - 5.0 Ton
2.0 - 4.0 ton (see note 4)
2.0 - 5.0 Ton
- 29" (737 mm) ( see note 2) Depth - 24-1/2" (623 mm)
240 Volts/60Hz/1-Phase
0.3
16" x 20" x 1" (nominal)