background image

Specifications & illustrations subject to change without notice or incurring obligations.
O’ Fallon, MO | Printed in U.S.A. (02/12)

709278A 

(Replaces 7092780)

inStaLLer: PLeaSe LeaVe tHeSe 

INSTRUCTIONS WITH THE EQUIPMENT OWNER.

Содержание C8BA Series

Страница 1: ...ing factor when installing this product and using common sense plays an important role as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper installation of the furnace or failure to follow safety warnings could result in serious injury death or property damage These instructions are primarily intended to assist qualified individuals experience...

Страница 2: ...ation of this unit Unqualified individuals should not attempt to interpret these instructions or install this equipment If you do not posses mechanical skills or tools call your local dealer forassistance Undernocircumstancesshould the equipment owner attempt to install and or service this equipment Failure to follow safety recommendations could result in possible damage to the equipment serious p...

Страница 3: ... could result in serious injury or property damage Improper servicing could result in dangerous operation serious injury death or property damage Beforeservicing disconnectallelectricalpower to the furnace and outdoor condensing unit When servicing controls label all wires prior to disconnecting Reconnect wires correctly Verify proper operation after servicing CAUTION The coil must be level to ens...

Страница 4: ... distributor body and hand tighten both components Mark a line on both bodies and then tighten an additional 1 4 turn using two wrenches The movement of the two lines will show how much the nut is tightened If a torque wrench is used tighten to 10 12 ft lbs or 14 16 Nm Connecting the Linesets 1 Route and cut both lineset tubes to proper length in accordance with the outdoor unit specifications Ver...

Страница 5: ...a minimum horizontal slope in the direction of discharge of not less than 1 vertical for every 10 ft of horizontal run During system checkout inspect the drain line and connections to verify proper condensate drainage Maintenance Service WARNING ELECTRICAL SHOCK FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage Improper servicing c...

Страница 6: ...ction Line in 3 4 3 4 7 8 Installed Orifice Size in 061 067 071 NOTES 1 Individual restrictors are available by part number PN664 where represents the size Example 664103 is a restrictor 0 103 in diameter 2 RefertosalesspecificationsheetsforListed Certifiedcombinationsofequipmentandrequiredaccessories 3 Refer to the current AHRI directory for certified ratings of split systems 4 Based on a nominal...

Страница 7: ...7 ...

Страница 8: ...ications illustrations subject to change without notice or incurring obligations O Fallon MO Printed in U S A 02 12 709278A Replaces 7092780 INSTALLER PLEASE LEAVE THESE INSTRUCTIONS WITH THE EQUIPMENT OWNER ...