Type 6
13
E
2010
Gear Pump
Pay attention to the following points:
1. See to utmost cleanliness
2. Even small pollution can cause damages
3. Always keep in mind that gear pumps are manufactered with highest
precision and that they should be handled with suitable tools only
4. Protection against corrosion
In case the gear pump is not in operation for some time, it should be
protected against surrounding influences.
S
Close inlet and outlet port
S
For protection against corrosion keep the dry and protect it by means of
preservation
Recommendation:
Pump inside:
Silicon oil AP 500 (comp. Wacker, Munich/ Germany)
Pump outside:
S
for short--term storage: Rivolta KSP (comp. Bremer& Leguil, Duisburg/
Germany)
S
for long.term storage: Aqua safe 30 (comp. Castrol, Mönchengladbach/
Germany)
For use and removal read the instructions for use of the anticorrosive
agents.