Tribomatic Modular Pump with Adapter
E
2000 Nordson Corporation
All rights reserved
343 545A
Issued 8/00
Manual 37-35
Perform routine maintenance as necessary.
1. Disassemble and thoroughly clean the pump and the pump adapter
components.
CAUTION:
Do not immerse O-rings in solvent. Solvents cause
O-rings to swell. Do not use solvent to clean the pump body.
CAUTION:
Do not scrape parts with sharp objects. Burrs or
scratches on contact surfaces may occur, which may contribute
to powder build-up or impact fusion.
2. Blow the parts clean with low pressure compressed air.
3. Wipe the parts with a clean, lint free cloth. If necessary, remove the
O-rings and moisten the cloth with water or isopropyl alcohol.
4. See Figure 1. When replacing the nozzle and throat holder, line up
the parts so that each flat is facing up.
5. Inspect the powder feed tubing and replace any pieces that are worn
or damaged. If powder is impact-fused inside the tubing, replace the
tubing.
Routine