OLED User Interface
50
Part 1128351_02
E
2020
Nordson Corporation
Defining Setback Settings
Setback, also known as Standby, reduces the temperature by a user-defined
temperature offset from all enabled external zones.
There are three types of Setback options, including:
S
Manual Enter/Exit Setback
S
Automatic System Setback
S
Manual Setback - Auto Exit Time
When the melter is in Setback, the System Status is Blue and the Master
Setback control LED is illuminated.
System
Status
Master Setback
Manually Entering/Exiting Setback
S
Press the
master control button to toggle On (enter) or Off (exit)
Setback.
NOTES:
S
You can use the Setback master control to exit out of any Setback mode.
S
Upon exiting Setback mode, the melter status returns to Run (or Ready)
when all enabled zones are within 5 degrees of set point and the Master
Pump Control is switched On.
S
Press
on the OLED panel to clear and reset any Alert, Fault, or
Stop condition.