Pressure
Runup
Pressure Settings
Pressure Mode
OLED User Interface
36
Part 1128351_02
E
2020
Nordson Corporation
Defining Pressure Runup Settings and Monitoring Alert
Settings
Use Pressure Runup to allow the system pressure to automatically adjust to
maintain the same adhesive output when the line speed changes. You can
optionally decide if you want to receive pressure alerts when the system
pressure, hydraulic or pneumatic exceeds the defined thresholds.
NOTES:
S
The melter will go into an Alert condition only if the pressure meets or
exceeds the high/low thresholds for more than 10 seconds.
S
You can change the pressure scaling from the
System Settings |
Preferences
. The default is
pneumatic
.
S
The
Set Point
is a read-only, calculated value.
S
Press
on the OLED panel to clear and reset any Alert, Fault, or
Stop condition.
Pressure Runup Output Settings
Enter the maximum/minimum pressure and line speed you want the system
to use for production.
1. Select
Output Setting
, press
>
and enter the following information:
S
Low Speed Pressure Setting:
Pressure
Default
Minimum
Maximum
PSI
20
0
90
BAR
1.38
0
6.21
kPa
138
0
621
S
Low Line Speed
Pressure
Default
Minimum
Maximum
Meter/
Minute
6.1
0
298.7
Feet/
Minute
20
0
980
Содержание ProBlue Flex