Recording System Configuration Data

 

CAUTION: 

It is imperative to record default system settings prior to servicing certain system components. To 

prevent component damage and minimize downtime after replacing components, take photos of the HMI Setup 

Screens while the equipment is fully operational. The data reflected by the screen shots can be utilized to 

restore key system settings. Refer to the 

HMI Screen Description Manual

 for an overview of HMI Control Panel 

Screens.  

 

Key system data to capture will appear on the following HMI Control Panel Screens: 

  Interlock Setup 

  Level 1 Setup Menu 

  Level 2 Setup Menu 

  Meter Setup 

  Miscellaneous Pressure Setup 

  Position Setup 

  Pressure Limits Setup 

  Pressure Sensor Calibration 

  Purge Setup 

  Shot Sequence Setup 

  Shot Setup 

  System Setup 

  Valve Setup 

 

Stroke Adjustment 

It may be necessary to adjust the stroke of the inlet and outlet valves. Loosen the stroke adjustment lock nuts 

and make fine adjustments to the stroke adjustment bolt until the desired shot pattern is achieved. Refer to the 

Customer Product Manual

 for an illustrative view of the stroke adjustment lock nut and bolt. 

CAUTION: 

Be careful not to fully tighten stroke bolt as this may impact the operation of the valve. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

6

Содержание Pro-Meter A2K

Страница 1: ...em Clear air tubing 0 25 inch 6 35 mm Cups for collecting material during bleed procedure approx 3 0 oz 85 05 g Dispense valve assembly TOOLS REQUIRED FOR INSTALLA TION Ratcheting wrenches Adjustable...

Страница 2: ...NG Any material injected into flesh can cause severe injury or death Keep body parts awayfrom material discharge ports If injection occurs seek medical attention immediately WARNING Operating faulty e...

Страница 3: ...Circuit Drawing and Customer Product Manual for additional information 4 On systems equipped with a lead lag plate properly adjust the lead lag plate Refer to Lead Lag Adjustment for additional infor...

Страница 4: ...electric foot switch may also be utilized to dispense material 22 Repeat steps 2 through 18 as necessary until material is air free 23 From the Cycle Control Screen proceed to the Main Menu HMI Contro...

Страница 5: ...to be entered into the control panel 1 Obtain factory serial number from pressure sensor NOTE The serial number is stamped on the pressure sensor 2 Utilize calibration record as a basis to enter contr...

Страница 6: ...r on the following HMI Control Panel Screens Interlock Setup Level 1 Setup Menu Level 2 Setup Menu Meter Setup Miscellaneous Pressure Setup Position Setup Pressure Limits Setup Pressure Sensor Calibra...

Страница 7: ...nections are properly fastened Be sure there is sufficient power to cycle the linear servo actuator shaft Reference the linear servo actuator equipment literature provided with this manual Pressure se...

Страница 8: ...ght date 2017 Nordson and the Nordson logo All other are registered trademarks of Nordson Corporation Pro Meter is a registered trademark of Nordson Corporation All other trademarks are the property o...

Отзывы: