![Nordson MicroCoat MC800 Series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/nordson/microcoat-mc800-series/microcoat-mc800-series_operating-manual_1704368032.webp)
MicroCoat MC800 Series System
32
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Technical Data
Controller Air Schematic
Oil Flow Schematic
9
Control air input from solenoid
4.1 bar (60 psi) min.
Valve nozzle air
Constant air input
4.1 bar (60 psi) min.
Tank air
Valve control air
Pilot valve
Regulator
0–30 psi
System pressure ON / OFF
Regulator
0–30 psi
Auto/Run
Manual/Setup
6
12
Pressure
switch
Fluid
inlet
Fluid
outlets
Flow
controls