Nordson MicroCoat MC800 Series Скачать руководство пользователя страница 28

MicroCoat MC800 Series System

28

www.nordsonefd.com   [email protected]

   800-556-3484    Sales and service of Nordson EFD dispensing systems are available worldwide.

Replacement Parts

MC785M Series Spray Valve Part Numbers

HM6X25MM
Hex head bolt, SS
#7023573

Push-in elbow
10-32 x 4 mm OD
#7007019

#7023567
hex head bolt
SS — brass tipped

MC785M: Standard fan air cap .046" #7021775
MC785M-WF: Wide fan air cap .046" #7021778

Tubing for MC785M
#7008007 4 mm — black
#7022171 4 mm — clear
#7008006 4 mm — white

Air cap retainer

nut #7021599

Needle #7021702

Spring locating washer

#7021704

Diaphragm return spring

#7021700

Diaphragm chamber cap

#7021698

Push-in elbow

10-32 x 4 mm OD

#7007019

Optional: Straight

push-in fitting

10-32 x 4 mm OD

#7021724

Fluid body #7021696

Push-in fitting

1/8 NPT x 4 mm OD

#7021718

Optional:

Push-in elbow fitting

1/8 NPT x 4 mm OD

#7021738

Viton O-ring
#7014765

Nozzle .046" 
#7021753

Diaphragm retaining nut
#7021709

Diaphragm #7021727

PTFE side
(blue-grey)

Mounting clamp
#7021742

Содержание MicroCoat MC800 Series

Страница 1: ...MicroCoat MC800 Series System Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www nordsonefd com Original Instructions...

Страница 2: ...of industrial dispensing experience Most questions you will have are answered in this manual However if you need assistance please do not hesitate to contact EFD or your authorized EFD distributor Det...

Страница 3: ...r Features 14 Tank Reservoir Features 16 System Assembly 17 Mount the Spray Valves 17 Spray Area Coverage 17 Installation Removal of Flow Control Block off Plug from Manifold 18 Set Up the Controller...

Страница 4: ...spray valves and the MicroCoat tank reservoirs are all produced to exacting specifications and thoroughly tested prior to shipment The MC785M series valves are designed for long life without maintena...

Страница 5: ...of electric shock Disconnect power before removing covers and or disconnect lock out and tag switches before servicing electrical equipment If you receive even a slight electrical shock shut down all...

Страница 6: ...ervicing high pressure equipment A jet of high pressure fluid can cut like a knife and cause serious bodily injury amputation or death Fluids penetrating the skin can also cause toxic poisoning Any in...

Страница 7: ...ot operate equipment unless safety guards doors and covers are intact and automatic interlocks are operating properly Do not bypass or disarm any safety devices Keep clear of moving equipment Before a...

Страница 8: ...witch first to prevent sparking Know where emergency stop buttons shutoff valves and fire extinguishers are located Preventive Maintenance As part of maintaining continuous trouble free use of this pr...

Страница 9: ...0 F Dispose of components according to local regulations after one time use Do not clean components with strong solvents MEK acetone THF etc Clean cartridge retainer systems and barrel loaders with mi...

Страница 10: ...bar 30 psi maximum Nozzle air regulator 2 07 bar 30 psi maximum Cycle rate Up to 60 per minute Pressure switch rating 20VA 240V Approvals CE Compliant Satisfies Machinery Directive 98 37 EC evaluated...

Страница 11: ...el MC686M 7023846 MC685M 7023843 MC687M 7023849 MC687M DFS 7023850 Capacity 3 8 L 1 gallon 7 5 L 2 gallons 19 L 5 gallons Construction Acrylic tank wall anodized aluminum end caps Type 304 stainless s...

Страница 12: ...MicroCoat MC800 Series System 12 www nordsonefd com info nordsonefd com 800 556 3484 Sales and service of Nordson EFD dispensing systems are available worldwide Declaration of Conformity...

Страница 13: ...operation Constant air pressure applied to the tank reservoir forces lubricant through precision fluid flow controls on the MC800 controller then out to the spray valves When the press is stamping a 3...

Страница 14: ...air solenoid must be properly installed to allow the MicroCoat System to run in Auto Run mode refer to pages 18 19 3 Tank Air Pressure Regulates air pressure in the lubricant reservoir For most lubri...

Страница 15: ...ort pressurizes the lubricant reservoir 8 Nozzle Air Air from this port is used to spray the lubricant 9 Valve Control Air Air from this port controls the opening and closing of the spray valves 10 Fl...

Страница 16: ...d to the press Emergency Stop Circuit Switch opens when tank level is near empty 2 Air Pressure Relief Valve Automatically exhausts air if tank reservoir pressure exceeds 2 76 bar 40 psi Also used to...

Страница 17: ...23866 shown on page 27 for precise valve alignment IMPORTANT If you loosen the air cap retainer nut to reposition the tabs be sure to retighten the nut with a wrench before operating the valve The wid...

Страница 18: ...ntrol manifold Tighten the manifold setscrew firmly Set screw on bottom of manifold Set Up the Controller 1 Place the controller and tank reservoir away from traffic areas and position the tank to all...

Страница 19: ...ontrol air connector Connect to press control circuit 3 way press air solenoid is continuously open when the press is stamping Flow requirement 0 06 m3 min 2 0 cfm at 4 14 bar 60 psi Five micron filte...

Страница 20: ...supplied group and wrap each valve tri hose to provide a neat installation and prevent damage due to loose hoses System Assembly continued Connect the Tank Reservoir and Lubricant Filter NOTE Refer t...

Страница 21: ...Control solenoid Air manifolds for single dual Single valve Dual valve LVLP valve Lubricant Nozzle air Control air 6 mm Filter regulator Plant air 4 mm 6 mm NOTE If both manifolds are being used with...

Страница 22: ...in series with the Emergency Stop Circuit from the press Following integration of this circuit the end user should review and test the fail safe operation by turning off the MC800 system pressure swit...

Страница 23: ...nstall the tank cap Prime the System 1 Set the System Pressure switch to On 2 Adjust the Tank Air Pressure regulator to 1 03 bar 15 psi Do not set pressure lower than 0 83 bar 12 psi 3 Turn the Nozzle...

Страница 24: ...ontrol knobs as needed to provide proper lubricant coverage Preventive Maintenance The MicroCoat System is designed for long life with minimal maintenance To ensure trouble free performance follow the...

Страница 25: ...he valve body 3 Remove diaphragm retaining nut and spring locating washer from the needle then remove and discard old diaphragm NOTE Install a new diaphragm 7021727 each time the valve is reassembled...

Страница 26: ...ith 0 100 psi 0 7 bar regulator 7023877 MC800 15 MicroCoat controller with 0 15 psi 0 1 bar regulator MicroCoat Fluid Manifolds Part Description 7008010 8101 accept up to 4 flow controls Manifold with...

Страница 27: ...minum stand Comes complete with all items necessary for stable mounting of reservoir and controller 43 H x 20 W Accessories Mounting Brackets 7023855 For mounting controller to MC7300 stand or press e...

Страница 28: ...fan air cap 046 7021778 Tubing for MC785M 7008007 4 mm black 7022171 4 mm clear 7008006 4 mm white Air cap retainer nut 7021599 Needle 7021702 Spring locating washer 7021704 Diaphragm return spring 70...

Страница 29: ...7017402 Toggle switch 10 7022243 Air pilot valve 11 7022165 Air output fitting 12 7022186 Fluid manifold outlet fitting 13 7022166 Fitting 1 8 NPT x 8 mm elbow 14 7008010 Fluid manifold w sensor 14 70...

Страница 30: ...One gallon 7020438 Acrylic tube 6 50 D x 16 35 L Two gallon 7022188 1 8 BSPP x 6 mm cap barb fitting tank outlet 7022175 Black urethane hose 7020442 Filler cap 7020436 Nickel plated brass drain plug 7...

Страница 31: ...r may not be pushed fully into the fluid outlet fitting on the rear panel of the controller Ensure connector is firmly seated Check fluid hose for kinks Valves do not turn on Supply pressure to contro...

Страница 32: ...dwide Technical Data Controller Air Schematic Oil Flow Schematic 9 Control air input from solenoid 4 1 bar 60 psi min Valve nozzle air Constant air input 4 1 bar 60 psi min Tank air Valve control air...

Страница 33: ...MicroCoat MC800 Series System 33 www nordsonefd com info nordsonefd com 800 556 3484 Sales and service of Nordson EFD dispensing systems are available worldwide Notes...

Страница 34: ...nozzles In no event shall any liability or obligation of EFD arising from this warranty exceed the purchase price of the equipment This warranty is valid only when oil free clean dry filtered air is...

Отзывы: