17
MEG® II Airless Spray Guns with 10 ft Cable
© 2021 Nordson Corporation
3.
Align the upper manifold so the stop screw (14) will go into the hole (2) when
tightened. Insert the upper manifold into the lower manifold. Make sure that the
wrench flats on the upper manifold are positioned as shown.
4. Tighten the stop screw.
5. Thread the manifold lock nut onto the upper manifold and tighten it securely.
6.
Thread the connector body (9) into the upper manifold and tighten it securely.
7.
Thread the gland nut (8) onto the connector body and tighten it securely.
8.
Carefully install the gun module (6), fitting the pins into the pin sockets in the upper
manifold.
9. Thread the gun module nut onto the gun module. Tighten the nut to 20-25 ft-lb
(27-34 N●m).
10.
Tighten the set screw (13).
11. Connect the wiring to the terminal block and fuse holder, if used.
7 8
9
10
11
13
12
2
3
4
5
6
14
Wrench Flats
1
Figure 6 Upper Manifold O-Ring Replacement
1. O-rings
2. Upper manifold groove
3. Upper manifold
4. O-ring
5. O-ring
6. Gun module
7. Electrical conduit
8. Gland nut
9. Connector body
10. Manifold lock nut
11. Lower manifold
12. Gun module nut
13. Set Screw
14. Stop screw