Nordson iDry
r
Series Induction Dryers
15
Part 1075452
−
04
E
2016 Nordson Corporation
Disabling Customer Interlock
If you do not wish to use the customer interlock, you can set the iDry system
to run with the signal from the motion sensor only.
1. Use the touch screen to go to the Navigation page.
2. Select Options. The Options Setup screen appears.
3. Touch the External Run Signal button to toggle it to IGNORED.
Optional Status Contact
See Figure 10. The status contact provides a Dryer Ready signal. It is
used in conjunction with the customer interlock. The contact indicates when
the dryer is off or in a fault condition. The contact is off when:
S
The dryer is turned off.
S
Any fault on the operator panel is activated.
Status Contact Connection:
Terminal 32 Output Contact (output)
Motion Sensor
See Figure 11. The motion sensor mounting is designed to locate the
sensor in either of the two positions shown. Use the 12:00 o’clock position
when possible. If a rod cage entry is used with a rod at 12:00 o’clock or if
an overhead guide interferes with the sensor line of sight, reposition the
motion sensor to the 30
_
position as shown.
Remove the protective cap (2) from the bottom of the motion sensor
head (1). Leave the cap attached to the sensor head for future use.
Adjust the motion sensor sensitivity as described on pages 18 or 19.
30
_
Position
12:00 O’Clock
Position
Sensor
Head
Cover
Figure 11 Motion Sensor Position and Cover (Keyence Sensor Shown)