Preparation
(contd)
3. Make sure your production line is ready to start. For both motion sensor
sensitivity adjustment and ramp mode power level adjustment you must
run can ends through the dryer.
4. Turn the main disconnect to the ON position.
5. Press the POWER button on the operator panel. The dryer powers up.
NOTE:
With the enclosure doors open and the door interlock switch
overridden, the Cooling Blower Fault LED lights. The motion sensor will
remain powered for making adjustments. The inverter will not turn on, so
product in the dryer while the fault LED is on will not be cured and must be
removed from production.
Keyence Motion Sensor Sensitivity Adjustment
WARNING:
Laser radiation. Do not look directly into the laser beam or its
reflection from can bodies. Doing so could result in serious eye injury.
1. Open the motion sensor module cover.
2. Make sure the protective cover is removed from the sensor head.
3. Run product through the dryer.
4. Press and hold the Set button until the Peak Hold (orange) LED and the
Setting monitor (green) start flashing. Release the button.
SET buttton
Peak Hold
(Orange) LED
Setting Monitor
Figure 13 Keyence Motion Sensor Module
The motion sensor should now be calibrated to your product. As can ends
pass under the sensor head, the motion sensor should blink and the Motion
indicator on the operator panel should flash.
If the sensitivity adjustment failed, repeat the procedure again. Clean the
sensor head lens with a clean soft cloth if necessary.