Encore PE 50-lb Feed Hopper
2
Part 1604293
−
01
E
2013 Nordson Corporation
Installation
Basic
1. Make sure the fluidizing drum (6) and cover (2) are securely clamped to the
body (3), and that all gaskets are undamaged and sealing properly.
2. Connect 10-mm flexible air tubing to the fitting labeled with the fitting on the
rear of the controller labeled with the hopper fluidizing icon (
). Connect the
opposite end of the tubing to the fluidizing air connector (5).
WARNING:
All electrically conductive equipment in the spray area must be
grounded. Ungrounded or poorly grounded equipment can store an electrostatic
charge which can give personnel a severe shock or arc and cause a fire or
explosion.
3. For stand-alone hoppers, connect the ground wire shipped with the hopper to
the ground stud (4). Connect the spring clip to a true earth ground.
For hoppers on a mobile powder system dolly, connect the dolly ground wire to
the ground stud (4).
4. Make sure the O-rings are installed correctly in the pump or adapter grooves.
Install the pump on or in the adapter with a slight twisting motion.
5. Connect the flexible vent hose shipped with the hopper to the vent hose
adapter (1). Secure the hose to the adapter with a hose clamp. Connect the
other end of the hose to the booth powder collector to prevent vented powder
from contaminating the room air.
Installing Additional Pumps
If you wish to install an additional pump, you must order a pump adapter and
pickup tube for it. Remove the plug from the cover and install the adapter, pickup
tube, and pump.