System Setup
3-7
Part 1604858-01
E
2013 Nordson Corporation
Use spiral-cut tube wrap to bundle the flow and atomizing air tubing to the
pumps, and the gun cable and electrode air wash tubing to the guns. Route
the tubing and cables to prevent damage and kinking.
1
2
3
4
5
6
7
8
9
10
11
L1
−
Black
L2
−
White
L1
−
Brown
L2
−
Blue
AC Common
−
Orange
120V/240V
−
Red
GND
−
Green/Yellow
Conveyor
Interlock
}
Only with Axis Controller
Multi-Gun Controller
−
Power, Air, and Gun Connections (rear cover and rear kick panel removed)
1. Air supply tubing
−
16mm blue
2. Gun cables
3. Gun air wash tubing
−
4mm clear
4. Pump flow tubing
−
8mm black
5. Pump atomizing tubing
−
8mm blue
6. Rear cover ground wire
7. Power
8. Auxiliary strain reliefs
9. Trigger/power distribution
panel
10. Axis Controller panel
(optional)
11. Gun controller panels
Note:
Each gun controller panel provides outputs for two Encore automatic spray guns. The Axis Controller is optional.
Refer to the Axis Controller manual for connections.
Содержание Encore LT Automatic
Страница 4: ...Change Record ii Part 1604858 01 E 2013 Nordson Corporation...
Страница 8: ...Table of Contents vi Part 1604858 01 E 2013 Nordson Corporation...
Страница 12: ...Safety 1 4 Part 1604858 01 E 2013 Nordson Corporation...
Страница 20: ...Description 2 8 Part 1604858 01 E 2013 Nordson Corporation...
Страница 34: ...System Setup 3 14 Part 1604858 01 E 2013 Nordson Corporation...
Страница 44: ...Operation 4 10 Part 1604858 01 E 2013 Nordson Corporation...
Страница 63: ...Wiring Diagrams 7 1 Part 1604858 01 E 2013 Nordson Corporation Section 7 Wiring Diagrams...
Страница 64: ...Wiring Diagrams 7 2 Part 1604858 01 E 2013 Nordson Corporation...