Problem
Possible Cause
Corrective Action
6.
Machine stop function
not working
Machine stop not enabled.
Enable the machine stop function by
pressing the Machine Control
Settings button on the touch-screen
panel. Configure the machine stop
settings.
Problem in the LogiComm control
system.
Refer to the LogiComm Control
System manual or the embedded
Help in the touch-screen panel to
troubleshoot.
7.
Machine cannot be
restarted after a stop
The machine-stop contacts in the
LogiComm control system need to
be reset.
Enable the machine stop function by
pressing the Machine Control
Settings button on the touch-screen
panel.
Check Trigger Operation
1. Slow down the production line until you can observe the yellow
TRIGGER LED on the control module turn on and off with each passing
product.
2. Verify that the LED turns on when the trigger detects the product’s
leading edge (or some other selected edge) and turns off when it detects
the trailing edge (or some other selected edge). If the light fails to turn
on or if it turns on and off more than once, refer to
Trigger Setup
under
Installation.