A16A Inside Stripe Gun
6
Part 107907-06
E
2020 Nordson Corporation
COATING
MATERIAL
SUPPLY
PUMP
HEATER
HIGH
PRESSURE
FLUID
FILTER
FLUID
PRESSURE
REGULATOR
PLANT
AIR
AIR FILTER
(5 MICRON)
AIR
PRESSURE
REGULATOR
AIR
DRYER
A16A
GUN
SENSOR
TIMER
24VDC
0.1 AMPS
CIRCULATION
VALVE
WELD
BODY
MAKER
SOLENOID
VALVE
Figure 2
Remotely Actuated System Block Diagram
Installation
WARNING:
Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
Tubing Preparation
NOTE:
The welding machine fluid and air lines must be configured before
connecting the gun.
1. Slip the nut and ferrule onto the tubing. Make sure the long straight end
of the ferrule is pointing towards the tube end.
2. Bottom the tubing against the tube stop in the fitting body.
3. Using oil, lightly lubricate the threads on the fitting body and the lead
and tail ends of the ferrule.
4. Pre-set the ferrule by screwing the nut down finger tight. Then, use a
wrench to tighten the nut 1
3
/
4
turns.
5. See Figure 3. Disassemble and inspect the ferrule/tube
compression (1).