Installation Instructions for Series 3100V Level Switch

E

2000 Nordson Corporation

All rights reserved

321 355A

Issued 5/00

41--3000--IS--65

1. Use the nut (1) and lock washer (2) to fasten the float switch (6) to the

base (5). See Figure 1.

4131107A

1

2

5

3

4

8

6

7

Fig. 1 Low-level Switch

1. Nut
2. Lock washer
3. Pan-head screws
4. Washer
5. Base

6. Float switch
7. Flat-head screws
8. Shield

2. Check the float switch to make sure the small embossed triangle is on

top.

3. Use the two flat-head screws (7) to attach the shield (8) to the base.

4. Use the pan-head screws (3) and lock washers (4) to fasten the

switch to the pump pan. See Figure 2.