background image

1604620 - EN 

Page 3 of 12

GENERAL DESCRIPTION

The Nordson diaphragm pump offers high volume delivery 

even at low air pressure and a broad range of material compat-

ibility options available. Refer to the model and option chart. 

Nordson pumps feature stall resistant design, modular air mo-

tor / fluid sections. 

Air operated double diaphragm pumps utilize a pressure dif-

ferential in the air chambers to alternately create suction and 

positive fluid pressure in the fluid chambers, ball checks insure 

a positive flow of fluid. 

Pump cycling will begin as air pressure is applied and it will 

continue to pump and keep up with the demand. It will build 

and maintain line pressure and will stop cycling once maxi-

mum line pressure is reached (dispensing device closed) and 

will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

 

EXCESSIVE AIR PRESSURE. Can cause pump 

damage, personal injury or property damage.

A filter capable of filtering out particles larger than 50 

microns should be used on the air supply. There is no lu-

brication required other than the “O” ring lubricant which is 

applied during assembly or repair.

If lubricated air is present, make sure that it is compatible 

with the “O” rings and seals in the air motor section of 

the pump.

 Viton

®

, PTFE

®

 and Hytrel

®

 are registered trademarks of the DuPont

®

  Company  Loctite

®

 is a registered trademark of Henkel Loctite Corporation 

  Santoprene

®

 is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P.  Lubriplate

®

 is a registered trademark of Lubriplate Division (Fiske Brothers Refining Company)   

OPERATING INSTRUCTIONS

Always flush the pump with a solvent compatible with 

MAINTENANCE

Certain parts are indicated which should be available for 

fast repair and reduction of down time.

Provide a clean work surface to protect sensitive internal 

moving parts from contamination from dirt and foreign 

matter during service disassembly and reassembly.

Keep good records of service activity and include pump 

in preventive maintenance program.

Service Kits are available to service 1. AIR SECTION, 2. 

FLUID SECTION, 3. BALL AND SEAT SECTION.

the material being pumped if the material being pumped 

is subject to “setting up” when not in use for a period of 

time.

Disconnect the air supply from the pump if it is to be in-

active for a few hours.

The outlet material volume is governed not only by the 

air supply but also by the material supply available at the 

inlet. The material supply tubing should not be too small 

or restrictive. Be sure not to use hose which might col-

lapse.

When the diaphragm pump is used in a forced-feed 

(flooded inlet) situation, it is recommended that a Check 

Valve” be installed at the air inlet.

Secure the diaphragm pump legs to a suitable surface to 

insure against damage by vibration.

TYPICAL CROSS SECTION

Figure 2

Содержание 1604629

Страница 1: ...imum Air Inlet Pressure 10 p s i g 0 69 bar Maximum Material Inlet Pressure 10 p s i g 0 69 bar Maximum Outlet Pressure 100 p s i g 6 9 bar Maximum Flow Rate flooded inlet 10 6 g p m 40 1 l p m Displa...

Страница 2: ...ctory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements Obtain Material Safety Data Sheets on all materia...

Страница 3: ...ont Company Loctite is a registered trademark of Henkel Loctite Corporation Santoprene is a registered trademark of Monsanto Company licensed to Advanced Elastomer Systems L P Lubriplate is a register...

Страница 4: ...1604613 1 GA 61 Outlet Mainfold 1604629 NPTF 1604615 1 GA 1604630 BSP 1604616 1 GA 63 Pipe Plug 1604629 NPTF 1604603 1 D 1604630 BSP 1604618 1 D 1604584 FLUID SECTION SERVICE KIT Item Description Qty...

Страница 5: ...evenly then re torque after initial run in Apply pipe sealant to threads Apply Loctite 242 to threads Apply Lubriplate to all O rings U cups and mating parts Apply anti seize compound to threads and...

Страница 6: ...s and 22 balls Remove 60 bottom manifold Remove 19 O rings 21 seats and 22 balls Remove 15 fluid caps Remove 6 diaphragm nut 7 or 7 8 diaphragms and 5 washer Remove 1 connecting rod from air motor Car...

Страница 7: ...S MUST FACE EACH OTHER Assemble 137 O rings to 136 large plug Assemble 137 and 166 O rings to 107 small plug Insert 111 spool into 136 large plug then insert 136 large plug into 135 valve block being...

Страница 8: ...pe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be non collapsible type capable of pulling a h...

Страница 9: ...1604620 EN Page of 12 ACCESSORIES 1604730WALL MOUNT BRACKET ASSEMBLY Wall Mount Bracket Washer 3 3 16 Lock Washer 3 10 Cap Screw 3 10 24 x 1 2...

Страница 10: ...NPSH FLOW RATE LITERS MIN 40 AIR CONSUMPTION IN LITERS SEC NPSH 37 5 2 1 0 1 6 2 0 12 15 Performance based on water at ambient temperature 0 4 0 2 0 1 0 18 9 8 4 0 50 100 150 200 0 25 50 75 100 0 2 4...

Страница 11: ...1604620 EN Page 11 of 12...

Страница 12: ...Page 12 of 12 1604620 EN...