Ejector Gun Controller
18
E
2001 Nordson Corporation
All rights reserved
1006453A
Issued 6/01
Manual 25-23
Follow these procedures to replace the power cable that connects the
keypad to the PLC.
1. Disconnect power at the knife disconnect and open the controller
door.
2. Unplug the communication cable (6) from the keypad (1).
3. Unplug the communication cable from the PLC (7).
4. Plug a new cable into the PLC and the keypad.
5. Close the controller door and restore the power connection at the
knife disconnect.
Follow these procedures to replace the PLC in the Ejector gun controller
enclosure.
1. Disconnect power at the knife disconnect and open the controller
door.
2. Disconnect the wires and communication cable (6) from the PLC (7).
3. Disconnect the PLC from the DIN rail and remove the PLC from the
controller enclosure.
4. Install the new PLC onto the DIN rail.
5. Connect the wires.
6. Download the most current Ejector gun program according to your
programming software literature, using the cables supplied for
downloading.
7. Put the PLC in the software RUN mode.
8. Plug in the communication cable.
9. Close the controller door and restore the power connection at the
knife disconnect.
Replacing the
Communication Cable
Replacing the PLC