![Nordson EFD Ultimus IV Series Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/nordson-efd/ultimus-iv-series/ultimus-iv-series_operating-manual_1704568027.webp)
Input / Output Connection
Voltage Initiate Circuit
The Ultimus IV workstation may be initiated with a 5 to 24 VDC signal across pins 1 and 2. These two input pins
are current-driven and optically isolated. From the Programmed Dispense mode, this signal can be momentary (no
less than 0.01 seconds) or maintained. In this mode, a new dispense cycle begins once the 5 to 24 VDC signal is
removed and then applied again.
When this input circuit is activated in the Manual mode, a continuous bead is dispensed until the signal is removed.
Mechanical Contact Initiate
The Ultimus IV can be initiated via the closure of mechanical contacts, such as a relay or switch, using pins 7 and 8.
The timing and actuation rules for the contact closure input are identical to the voltage initiate input description.
End-of-Cycle Feedback Circuit
Upon completion of a dispense cycle, a solid-state switch closes and remains closed until the next dispense cycle.
This circuit is normally closed when a dispense cycle is not active. Pins 3 and 4 of this circuit can be used to signal
back to a host computer, start another device in sequence, or initiate other operations that need to be tied into the
completion of the dispense cycle.
The circuit is an optically isolated transistor output designed to operate between 5 to 24 VDC, 100 mA maximum.
Pin Function
1. Voltage in, 5–24 VDC (22 mA at 24 VDC)
2. Voltage initiate -
3. End-of-cycle feedback , 5–24 VDC (100 mA maximum)
4. End-of-cycle feedback output -
5. 24 VDC (100 mA maximum)
6. 24 VDC supply - (ground)
7. Contact c, 10 mA
8. Contact closure - (ground)
NOTES:
• An 8-pin DIN connector and cable assembly is available. Order Nordson EFD P/N 7017143.
• Ultimus IV operation is identical for dispense initiation from I/O inputs or the foot pedal.
• Pins 6 and 8 of the I/O connector are internally connected to the signal ground.
Back panel I/O pin diagram
Ultimus IV Series Dispensers
27
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.