Install the Controller and Test the Operation

1.  Use supplied power cord and power supply to connect power to the 

Power input port on the back of the V10D controller.

NOTE:

 An optional 24 VDC power cable is available. Refer to "Part 

Numbers" on page 19 for the cable part number and connection 
information.

2.  Connect the dispensing valve to the controller using the cable supplied 

with the valve.

3.  Switch on the controller using the ON/OFF switch. The red Power LED 

illuminates.

4.  Start dispensing using the factory settings, or adjust the dispensing 

parameters using the V10D software:

•  Refer to "Parameter Factory Settings" on page 16 for the factory 

settings.

•  Refer to "Setup" on page 14 to change parameters as needed for 

your application.

5.  As needed, use the push-button board to test the controller operation. 

Refer to "Use the Push-Button Board to Test the Controller Operation" 
on page 18
.

Setup

NOTES:

•  The push-button board can be used for testing. Refer to "Use the Push-

Button Board to Test the Controller Operation" on page 18.

•  For serial operation, or to incorporate the controller into a special 

machine, I/O signals from a PLC can be connected to the Remote 
input, instead of to the push-button board. For the Remote input pin 
assignment, refer to "Input / Output Connector Pin Assignments" on 
page 20.

Install Software and Connect the PC

1.  Install the driver software for the USB-to-RS232 adapter cable on a 

personal computer (PC).

2.  Go to 

www.nordsonefd.com/LiquidynV10D

 to obtain the V10D 

software.

3.  Install the V10D software on the same PC used in step 1.

4.  Run the "Liquidyn_V10D_Setup" installer and follow the instructions.

5.  Connect the USB-to-RS232 adapter cable to the V10D controller and 

to the PC.

Continue to "View or Change Parameters" on page 15 to view or 
change the V10D controller settings using the V10D software.

ON / OFF switch

Содержание Liquidyn V10D

Страница 1: ...Liquidyn V10D Controller Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www nordsonefd com...

Страница 2: ...strial dispensing experience Most questions you will have are answered in this manual However if you need assistance please do not hesitate to contact EFD or your authorized EFD distributor Detailed c...

Страница 3: ...Equipment Specific Safety Information 10 Specifications 11 Operating Features 12 Front Panel Components 12 Rear Panel Components 12 Installation 13 Unpack the System Components 13 Install the Control...

Страница 4: ...is a highly accurate multi functional controller for use with Liquidyn micro dispensing valves The controller is capable of managing up to four different dispensing programs Program parameters can be...

Страница 5: ...f electric shock Disconnect power before removing covers and or disconnect lock out and tag switches before servicing electrical equipment If you receive even a slight electrical shock shut down all e...

Страница 6: ...vicing high pressure equipment A jet of high pressure fluid can cut like a knife and cause serious bodily injury amputation or death Fluids penetrating the skin can also cause toxic poisoning WARNING...

Страница 7: ...vice equipment unless you are qualified Do not operate equipment unless safety guards doors and covers are intact and automatic interlocks are operating properly Do not bypass or disarm any safety dev...

Страница 8: ...tch first to prevent sparking Know where emergency stop buttons shutoff valves and fire extinguishers are located Preventive Maintenance As part of maintaining continuous trouble free use of this prod...

Страница 9: ...lations after one time use Do not clean components with strong solvents MEK acetone THF etc Clean cartridge retainer systems and barrel loaders with mild detergents only To prevent fluid waste use Nor...

Страница 10: ...ct heat sources Fluid Compatibility Use only for the micro dispensing of high to low viscosity fluids or pastes Ensure that all fluid carrying parts and sealings are resistant to the dispensing materi...

Страница 11: ...ture 25 60 C 13 140 F Product classification IP40 Protection Class III Approvals CE RoHS WEEE China RoHS RoHS China RoHS Hazardous Material Declaration Part Name Toxic or Hazardous Substances and Elem...

Страница 12: ...e air power Valve connection for valve power USB to RS232 interface Port Description Power 7 pin socket from binder power supply connection Air Valve 3 pin M8 nozzle air power input cable connection J...

Страница 13: ...e worldwide 1 Liquidyn V10D controller 2 Power cord and power supply external power adapter 3 USB to RS 232 COM adapter cable and driver software 4 Push button board for testing Installation Use this...

Страница 14: ...s needed use the push button board to test the controller operation Refer to Use the Push Button Board to Test the Controller Operation on page 18 Setup NOTES The push button board can be used for tes...

Страница 15: ...hanges under the NEW VALUES column Refer to About the V10D Controller Parameters on page 16 for information about parameters 7 Click ENTER NEW VALUES to save the changes NOTE The controller can store...

Страница 16: ...Pulse Time 0 1 to 10 000 ms Corresponds to the electrical actuation time of the valve Must be adapted to the corresponding valve type jet type or dot type NOTE Refer to Pulse Time Setting for Jet Typ...

Страница 17: ...e valves corresponds to the opening time of the valve The dispensing volume can be adjusted by adjusting the Pulse Time Setup continued Pulse Time Setting for Dot Type Valves The Pulse Time must be 2...

Страница 18: ...programmed 7 START4 Runs Program 4 The valve dispenses as programmed Use the Push Button Board to Test the Controller Operation The V10D controller functions can be tested using the push button board...

Страница 19: ...V 3 75 Amp 7825175 Power cable banana plug 24V 2 m NOTE This cable can be used to connect power to the controller in place of the supplied power cord Note the pin assignments Red 24 VDC Black Mass Tro...

Страница 20: ...mote I O using the push button board Pin Direction Assignment Description 1 Output 24 VDC Out max 0 25 A Operating voltage 2 NC Not assigned 3 Input START1 Starts Program 1 4 Input STOP Stops 5 Input...

Страница 21: ...ldwide Power Supply Input Pin Assignments Pin Assignment Description 1 NC Not assigned 2 24 VDC Operating voltage 3 NC Not assigned 4 NC Not assigned 5 24V GND Operating voltage ground 6 NC Not assign...

Страница 22: ...m this warranty exceed the purchase price of the equipment This warranty is valid only when oil free clean dry filtered air is used Nordson EFD makes no warranty of merchantability or fitness for a pa...

Отзывы: