General information

Our surrounds are all made of non-combustible  

materials. All our inserts/stoves are tested according 

to the latest European requirements and also to the 

Norwegian SINTEF standard, which includes particle 

tests.  Several European countries however have 

individual rules for installation of inserts, stoves and 

fireplaces. You as a client are totally responsible 

for the fulfilling of these local rules concerning 

the installation in your region/ country. Nordpeis 

(Northstar) is not responsible regarding correct 

installation. 

You should check local regulations concerning:

•  distance from firebox to combustible/flammable  

  materials

•  insulation materials/requirements between 

  fireplace surround and back wall

•  size of floor plates in front of fireplace/stove if  

  required

•  fluepipe connection between firebox and chimney 

•  insulation requirements if fluepipe goes through  

  flammable wall such as a wood wall.

Adjustment

We recommend to stack the surround without glue in 

order to adjust the insert prior to perforating the chimney 

for the flue connection. Use a spirit level to ensure that 

the surround is mounted straight. The insert will expand 

with heat and for this reason the surround must not rest 

on the insert. (Above the insert there must be a gap 

of 3 to 5 mm. Laterally there is no need for gaps, but 

between the lower part of the insert and the surround 

there must be a gap of at least 2 mm.)

Floor plate

A fireproof floor plate must be put in front of the fireplace

if the floor is of a combustible material.

Powder glue for filling

This is used to repair any notches or wounds in the 

concrete. Mix the provided powder glue with water (the 

consistency of the glue should be that of tooth paste). 

Before you start, use a damp sponge to wet the concrete 

surface. This will remove dust and provide for better 

adhesion. Fill in any uneven surfaces.

Acrylic glue

This is used for gluing the elements towards wall, gluing 

the elements together and for filling joints.

Painting

The surround can be painted 24hrs after that it has been 

assembled. Any surface that has been filled needs to be 

smoothened with fine sand paper. Use latex or acrylic 

based paint (emulsion paint).

Marble/granite

Clean the plates with mild soapy water and remove any 

residue of spilled glue.

Never use acid/abrasive materials, as this will damage 

the surface and polishing.

It is important to use detergent/sealant that is approved 

for marble for cleaning and sealing.

Scratches in dark marble can be coloured with a pencil. 

A professional stone centre can help you with different 

products for surface treatment of the stone.

Fine Fissures

Settlement  cracks can appear during the first year of 

new built houses. For this reason, very thin fissures 

could appear in the joints between the elements, the 

firewall and the chimney. This is entirely normal and 

no reason for concern. These small fissures can be 

removed by renewing the joint. Scrape out the joint with 

a joint scraper and then vacuum clean to remove all the 

dirt. Inject acrylic  into the joint and even out by using the 

fingertip with some soapy water. After about 24 hours 

the joint can be repainted.

Smaller damages

These are successfully repaired with the provided 

powder glue. If the damage is deep, we recommend 

filling twice in order to avoid sinking. Fill smaller cracks 

and uneven surfaces with a float or a brush. Smoothen 

the surface with a damp sponge or sand paper.

For your own safety, comply with the assembly 

instructions. All safety distances are minimum distances.

Installation of the insert must comply with the rules and

regulations of the country where installed. Nordpeis AS

is not responsible for wrongly assembled inserts.

We accept no liability for typographical errors and

changes.

Содержание Verona Corner

Страница 1: ...Art no FP VER02 201 Nordpeis 30 03 2011 Verona Hjørne Verona Corner NO Monteringsanvisning 2 GB Installation manual 4 ...

Страница 2: ...dig montert etterfyll skjøtene mellom elementene med akryl og jevn fugen med en såpevåt svamp eller finger slik at det blir en tydelig fordypning mellom elementene FIG Z Småskader Grunnet transport og håndtering kan det oppstå små skader på peisen Dette kan repareres med medfølgende fliselim For perfekt resultat kan du sparkle og slipe med egnet sparkelmasse utenpå fliselimet Mindre sår og ujevnhe...

Страница 3: ...rever Brannmuren må da forlenges til angitt sikkerhetsavstand er oppnådd Minimum avstand fra dør på innsatsen til brennbar vegg er 300 mm Minimum avstand fra toppen av utluftningen til tak av brennbart materiale er 350 mm Minimum avstand fra røykrør røykklokke til brennbar vegg er 300 mm Dersom røykrøret skal føres gjennom brennbar vegg må det mures minimum 230 mm murverk mellom rør og brennbar ve...

Страница 4: ...onge to wet the concrete surface This will remove dust and provide for better adhesion Fill in any uneven surfaces Acrylic glue This is used for gluing the elements towards wall gluing the elements together and for filling joints Painting The surround can be painted 24hrs after that it has been assembled Any surface that has been filled needs to be smoothened with fine sand paper Use latex or acry...

Страница 5: ... in the door to a lateral wall must be of at least 300 mm The distance between the top of the convection air outlet and roof of inflammable material must be at least 350 mm The distance to any inflammable material in front of the opening of the insert must be of at least 1 m Assembly instructions FIG 3 FIG 15 FIG 4 If the fireplace is connected to a chimney at the top the smoke lid must be moved t...

Страница 6: ...6 Verona Hjørne Verona Corner mm 1900 438 5 6 0 795 800 716 1065 2 6 5 Fig 1 ...

Страница 7: ...7 Fig 2 350 350 300 300 Brannmur Brandmur Turvaetäisyydet Firewall Brennbart materiale Brændbart materiale Brännbart material Palavasta materiaalista Combustible material 560 770 1900 1900 65 65 ...

Страница 8: ...8 Fig 5 Fig 6 2 3 3 90 Fig 3 Fig 4 122 mm 1 2 3 ...

Страница 9: ...9 Fig 7 Fig 8 4 6 5 Fig 9 Fig 10 7 X4 8 2 mm 2 mm 2 mm 8 438 mm ...

Страница 10: ...10 Fig 13 Fig 11 Fig 12 Fig 14 11 10 x 2 12 13 11 9 3 mm ...

Страница 11: ...1 2 Fig Z Fig 15 ...

Страница 12: ...Nordpeis AS Gjellebekkstubben 9 11 N 3420 LIERSKOGEN Norway www nordpeis no ...

Отзывы: