9
GB
1. Prior to assembling the insert
Our surrounds are all made of non-combustible
materials. All our inserts/stoves are tested according
to the latest European requirements and also to the
Norwegian SINTEF standard, which includes particle
tests. Several European countries however have
individual rules for installation of inserts, stoves and
fireplaces.
The client is entirely responsible for the fulfilling of
these local rules concerning the installation in his
region/country. Nordpeis (Northstar) is not responsible
regarding correct installation. You should check local
regulations concerning: distance from firebox to
combustible/flammable materials, insulation materials/
requirements between fireplace surround and back wall,
size of floor plates in front of fireplace/stove if required,
fluepipe connection between firebox and chimney
and insulation requirements if fluepipe goes through
inflammable wall such as a wooden wall.
For your own safety, comply with the user
manual. All safety distances are minimum
distances. Installation of the insert must comply
with the rules and regulations of the country
where installed. Nordpeis AS is not responsible
for wrongly assembled inserts.
Chimney Draught
Compared with older models, the clean burning inserts
of today put significantly higher demands on the
chimney. Even the best insert will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature, air
supply as well as the height and inner diameter of the
chimney. The diameter of the chimney should never
be less than that of the flue/chimney collar. At nominal
effect there should be a negative pressure of 14 to 25
Pascal.
The draught increases when:
The chimney becomes warmer than the outside air
•
The active length of the chimney is increased (over
•
the hearth)
Good air supply to the combustion
•
It can be difficult to obtain the right draught conditions
in case the chimney is too large in relationship to the
fireplace, as the chimney does not heat up well enough.
If possible, insert a smaller chimney pipe. Draught that
is too strong can also be controlled with a damper.
Floor under the fireplace
Ensure that the floor where the fireplace is placed can
withstand the load with regards to the total weight of the
fireplace. If unsure, contact the local building authorities
or a builder for review / approval. When mounting the
fireplace on a floating wooden floor, the floorboards
under the fireplace should be removed to avoid that the
1. Prior to assembling the insert
9
Chimney Draught 9
Floor under the fireplace
9
Floor plate
10
2. Technical Information
10
3. Distance to combustible material
10
4. Assembly
10
Assembly instructions for the insert
10
Flue outlet
10
Connection of the flue
11
Operating control
11
Thermotte® plates
11
Assembly instructions for the surround
11
Smaller damages
11
Painting the surround
11
Fine fissures
11
5. Lighting the fire for the first time
12
6. Maintenance
12
Cleaning and inspection
12
Ashes
12
Door and glass
12
Recycling of the refractory glass
12
7. Warranty
13
8. Advice on lighting a fire
13
Some advice in case of combustion problems
14
INDEX
EC CONFORMITY DECLARATION
Date of issue: 15.07.2010
Identification:
Nordpeis NI-26
Product type:
Fireplace insert
Insert type:
Steel fireplace insert burning solid fuel
Fuel type:
Firewood only - see manual
Flue gas temperature:
313 ºC
CO content at 13 % O
2
:
0,07 %
Thermal output, nominal value: 5,0 kW
Energy efficiency:
79,3
%
Safety measurements:
Only to be used in non-combustible surrounds.
Must be used in accordance with user manual.
Minimum distance to adjacent
combustible materials:
Must be placed in accordance with user manual.
Country
Classifications
Test standard
Approved by
EUR
Intermittel
EN 13229
RRF
Stian Varre
General manager, Nordpeis AS
Conformity declaration issued by:
Company name:
Nordpeis AS
Address:
Gjellebekkstubben 9/11
Postal:
N-3420 Lierskogen
Country:
Norway
Phone:
(+47) 32 24 47 00
Fax:
(+47) 32 24 47 11
Web:
www.nordpeis.no
E-mail:
Rapport Nr. RRF - 29 09 2201
Inspection code: 1625
Rhein-Ruhr Feuerstättenprüfstelle GmbH
Am Technologiepark 1, D-45307 Essen
Содержание NI-26
Страница 45: ...45 2000 600 641 1240 336 Ronda mm...
Страница 46: ...46 600 400 50 50 50 FIG 1 mm...
Страница 48: ...48 X FIG 3 FIG 4...
Страница 49: ...49 FIG 5A FIG 6 FIG 7 FIG 5B FIG 8 FIG 9A FIG 9B...
Страница 50: ...50 FIG 10 FIG 11A FIG 11B FIG 12 G H F I...
Страница 51: ...51 FIG 14 FIG 17 FIG 15 FIG 13 124 mm 2 1 3 FIG 16 2 4 4...
Страница 53: ...53 FIG 21 6 2 mm FIG 23 FIG 22 8 FIG 24 7 8 8 8 9 3 mm x2...
Страница 54: ...54 1 2 Fig Z FIG 25 10...
Страница 55: ...55...
Страница 56: ...56 Nordpeis AS Gjellebekkstubben 9 11 N 3420 LIERSKOGEN Norway www nordpeis no...