the appliance from the mains electrical 

supply.

•  Remove the burner caps and the 

adapters.

•  Use a 7 mm spanner to unscrew the 

injectors.

•  Replace the injector with the ones from 

the gas conversion kit, with the correct 

diameters for the type of gas that is 

going to be used, according to the gas 

injector table.

Adapter

Spanner

Injector

Cup

Burner cap

Adjusting the reduced flame position

First of all, make sure that the appliance 

is unplugged from the mains electrical 

supply and that the gas feed is open. The 

minimum flame position is adjusted with a 

flat screw located on the valve. For valves 

with a flame failure safety device, the screw 

is located on the side of the valve spindle 

as shown in the figures. For valves without 

a flame failure safety device, the screw is 

located inside the valve spindle as shown 

in the figure. To make adjusting the flame 

position easier, we recommend that you 

remove the control panel (and the micro 

switch if your model has one) during the 

alteration.

To determine the minimum position, ignite 

the burners and leave them on in the 

minimum position. With the help of a small 

screwdriver, fasten or loosen the bypass 

screw by around 90 degrees. When the 

flame has a length of at least 4mm, the gas 

is well distributed. Make sure that the flame 

does not die out when passing from the 

maximum position to the minimum position. 

Create an artificial wind with your hand 

towards the flame to see if the flames are 

stable.

The bypass screw must be loosened for 

conversion from LPG to NG. For conversion 

from NG to LPG, the bypass screw must be 

tightened. Make sure that the appliance is 

unplugged from the mains electrical supply 

and that the gas feed is open.

Valve with flame failure device

Bypass screw

Valve with flame failure 

device Bypass 

screw

Valve without flame 

failure device

Bypass 

screw (Inside 

the hole)

Changing the gas inlet

For some countries, the gas inlet type 

can be different for NG/LPG gases. In 

this case, remove the current connection 

components and nuts (if any) and connect 

the new gas supply accordingly. In all 

conditions, all components used in gas 

connections should be approved by local 

and/or international authorities. In all gas 

connections, refer to the “Assembly of 

gas supply and leakage check” clause 

explained above.

2.5. 

eleCtriCal ConneCtion 

anD Safety (if available)

WARNING:

 The electrical connection 

of this appliance should be carried out 

by an authorised service person or 

qualified electrician, according to the 

instructions in this guide and in compliance 

with the current local regulations.

WARNING: THE APPLIANCE MUST 

BE EARTHED.

•  Before connecting the appliance to the 

power supply, the voltage rating of the 

appliance (stamped on the appliance 

identification plate) must be checked for 

correspondence to the available mains 

Содержание HGX703IX

Страница 1: ...Hob User Manual EN HGX703IX...

Страница 2: ...r property damage risk IMPORTANT Operating the system correctly Thank you for choosing this product This User Manual contains important safety information and instructions on the operation and mainten...

Страница 3: ...nstallation of the Hob 11 2 3 Gas Connection 12 2 4 Gas Conversion If available 13 2 5 Electrical Connection and Safety If available 14 3 PRODUCT FEATURES 16 4 USE OF PRODUCT 17 4 1 Use of gas burners...

Страница 4: ...vision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children should not play with the appliance Cleaning and user maintenance should not be made by...

Страница 5: ...repair work that is carried out by unauthorised technicians may be dangerous Do not alter or modify the specifications of the appliance in any way Inappropriate hob guards can cause accidents Before c...

Страница 6: ...y Since the glass may break care should be taken when cleaning Avoid hitting or knocking the glass with accessories Make sure that the supply cord is not trapped or damaged during installation If the...

Страница 7: ...ance i e cabinets must be able to withstand a minimum temperature of 100 C The temperature of the bottom surface of the hob may rise during operation therefore a board must be installed underneath the...

Страница 8: ...opening a window or for more effective ventilation for example increasing the level of mechanical ventilation where necessary 1 4 During Cleaning and Maintenance Make sure that your appliance is swit...

Страница 9: ...be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative c...

Страница 10: ...air in which case no permanent ventilation is required For rooms with a volume greater than 10 m3 no permanent ventilation is required Important Regardless of room size all rooms containing the applia...

Страница 11: ...of the appliance ensuring that there is no access to the base of the appliance The appliance can be placed close to other furniture on condition that in the area where the appliance is set up the furn...

Страница 12: ...A C B t t 20 mm 2 3 Gas Connection Assembly of gas supply and leakage check Connect the appliance in accordance with applicable local and international standards and regulations First check what type...

Страница 13: ...d fixed while rotating the counter part Use appropriately sized spanners for a safe connection For surfaces between different components always use the seals provided in the gas conversion kit The sea...

Страница 14: ...t when passing from the maximum position to the minimum position Create an artificial wind with your hand towards the flame to see if the flames are stable The bypass screw must be loosened for conver...

Страница 15: ...n leads The supply cord should be kept away from hot parts of the appliance and must not be bent or compressed Otherwise the cord may be damaged causing a short circuit If the appliance is not connect...

Страница 16: ...6 3 PRODUCT FEATURES Important Specifications for the product vary and the appearance of your appliance may differ from that shown in the figures below List of Components 1 Gas Burner 2 Control Panel...

Страница 17: ...nds before re igniting an extinguished gas burner 4 2 Hob Controls Hob burner The knob has 3 positions off 0 maximum big flame symbol and minimum small flame symbol Ignite the burner with the knob in...

Страница 18: ...ff the appliance and allow it to cool before cleaning is to be carried out General Instructions Check whether the cleaning materials are appropriate and recommended by the manufacturer before use on y...

Страница 19: ...Parts if available Clean the stainless steel parts of your appliance on a regular basis Wipe the stainless steel parts with a soft cloth soaked in only water Then dry them thoroughly with a dry cloth...

Страница 20: ...ed Also check that other kitchen appliances are working Flame colour is orange yellow Burner cap and crown are not assembled correctly Different gas compositions Ensure the burner parts have been plac...

Страница 21: ...l h 218 1 g h MEDIUM BURNER DIA of INJECTOR 1 100mm 97 65 NOMINAL RATING KW 1 75 1 75 CONSUMPTION 166 7 l h 127 2 g h MEDIUM BURNER DIA of INJECTOR 1 100mm 97 65 NOMINAL RATING KW 1 75 1 75 CONSUMPTI...

Страница 22: ...ology 3 Gas Size 3 cm Semi Rapid Energy Efficiency 3 59 0 Heating Technology 4 Gas Size 4 Rapid Energy Efficiency 4 57 0 Heating Technology 5 Gas Size 5 Wok Energy Efficiency 5 56 0 Energy Efficiency...

Страница 23: ...52237305...

Отзывы: