8
Electrical connection of your hob
.
Before proceeding with the electrical connection, verify that the current
carrying capacity of the system and the socket is adequate for the maximum
power rating of the hob.
·
Electrical installation of the residence and the electrical current plug in
use must be earthed and conform with safety regulations.
·
If there is no dedicated hob circuit and fused switch, they must be installed
by a qualified electrician before the hob is connected.
·
Switch must be easily accessible once the hob has been installed.
·
Do not use adaptors, multiple sockets and/or extension leads.
·
This appliance conforms with the requirements ofthe following EEC
Directives:
1. Vitroceramic hob EEC/73/23 and 93/68, EEC/89/336 relating to
radio interference,
2. EEC/89/109 relating to contact with foods.
·
The electrician must provide a fused
double-pole
switch, which disconnects
both the line (live) and neutral conductors with a contact separation of at
least 3,0 mm and rated 30A.
All manuals and user guides at all-guides.com