ENGLISH
WIND AIR KIT - FORCED VENTILATION COMPONENTS/EXCLUDING DIFFUSERS
WIND-AIR - DIFFUSERS
SHADE
diffuser for WIND-AIR system with fixed regulation.
WAVE
diffuser for WIND-AIR system with fixed regulation.
1
- Motor group (no.2 pieces)
2
- Regulator (no.1 piece)
3
- Regulator wall box (no.1 piece)
4
- Galvanised coupling D.120 mm
(no.2 pieces)
1
2
3
4
5
6
7
8
9
1
5
- Galvanised angular element for motor group fixing
(no.2 pieces)
6
- Pipe clamp band stainless steel D.60 -175 mm
(no.4 pieces)
7
- Stapled aluminium pipe D.120 mm - L.min 0,5 m,
L.max 1,5 m (no.2 pieces)
8
- Motor electric wiring (no.2 pieces)
9
- Temperature probe with electrical
cable 2.5 m.
OPTIONAL
ventilation kits can be installed on our products to improve the distribution of heat through ventilation of the installation
environment or the adjacent room.
The Wind Air Kit consists of two vents for forced ventilation fitted with a fan, a temperature probe and a regulator that controls the two fans
of the air vents at the same time.
Ignition and regulation are managed by the dedicated regulator supplied which must be installed far away from direct heat sources.
The probe installed in one of the two ventilation outlets, in addition to controlling the ventilation in AUTOMATIC mode, performs a SAfETY
control by operating the two fan motors when the air temperature exceeds the maximum permitted value.
NOT INCLUDED IN THE WIND AIR KIT. TO BE ORDERED SEPARATELY!