Picture 4
Figura 4
Abbildung 4
Figure 4
TERMOSUPREMA COMPACT DSA / ITALY TERMO DSA
58
2 m
10 m
1
m
4
1300
m
m
500
m
m
90°
1300
m
m
500
m
m
90°
a
a
COMIGNOLI DISTANZE E POSIZIONAMENTO UNI 10683
CHIMNEY CAPS - DISTANCES AND POSITIONING UNI 10683
SCHORNSTEINE ABSTÄNDE UND STELLUNG UNI 10683
TETES DE CHEMINEE ET POSITIONNEMENT UNI 10683
Inclinazione del tetto
Inclination of the roof
Dachneigung
Inclinaison du toit
a
>10°
5
Il comignolo non deve avere ostacoli entro i 10 m da muri, falde ed
alberi. In caso contrario innalzarlo almeno di 1 m sopra l’ostacolo.
Il comignolo deve oltrepassare il colmo del tetto almeno di 1 m.
The chimney cap must not show hindrances within 10 m from walls,
pitches and trees. Otherwise raise it of at least 1 m over the hindran-
ce. The chimney cap must exceed the ridge of the roof of at least 1 m.
Der Schornstein muss keine Hindernisse innerhalb 10m von
Mauern, Schichten und Bäumen. Anderenfalls der Schornstein
mindestens 1m über das Hindernis stellen. Der Schornstein
muss den Firstträger um mindestens 1m überschreiten.
La tête de cheminée ne doit pas avoir d’obstacles dans les 10 m
depuis les murs, nappes et arbres. Au cas contraire il faut soulever
la tête de cheminée d’au moins 1 m au dessus de l’obstacle. La tête
de cheminée doit surmonter la ligne de faîte du toit d’au moins 1 m.
5