HOOD OR ADJACENT ROOM VENTILATION
The
product
can distribute the heated air by means of NATURAL or FORCED CONVECTION, in the latter case using the OPTIONAL ventilation
kit -
WIND AIR KIT
(see separate instructions).
DURING THE INSTALLATION PHASE, IT IS NECESSARY TO CHOOSE THE TYPE OF CONVECTION
NATURAL CONVECTION:
The cover has outlets for the connection of heat-resistant pipes (“NOT supplied”).
It is not recommended to install the WIND AIR KIT after having removed the knockouts
Figure 10
- A
.
To facilitate the natural circulation of hot air, the knockouts must be removed from the lower part of the product’s outer casing (
Figure 10
-
B
)
FORCED CONVECTION:
By installing the OPTIONAL ventilation kit - WIND AIR KIT, it is possible to distribute the warm air in the adjacent rooms (see separate
instructions).
DO NOT REMOVE THE KNOCKOUTS
Figure 10
- A
.
CONNECTION OF THE HEAT-RESISTANT HOSES - NOT SUPPLIED
.
a) Drill holes in the wall or existing hood to allow for the passage of the flexible hoses (fireproof NOT supplied) with the relative vents;
b) secure the hoses to the relative collars and outlets using clamps;
c) each hose must not be longer than 1.5 m for natural ventilation and 8 m for forced ventilation, it must be insulated with insulating
materials to avoid noise and heat dispersion;
d) the outlets must be positioned at a height of at least 2 m from the floor, to prevent the warm air coming out from hitting people;
respect the distance of the convection openings in accordance with local construction regulations
;
e) the lengths of the ducting hoses must be the same length to avoid having different amounts of air distributed from each outlet.
Rev.00
: for combination with the WIND-AIR KIT, txt from INS.CRY and letter c) 8 m and not 4m, and txt Fan maint.-connect.